Print Report | Back to Sample Detail

Sample Record for 2026-07-22-8

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000511 DEA: 06487404 EFIS: 0616000029 QA Service Level: 1
DIST-CO-RTE-PM: 06-TUL-99-35.8/37.1
Work Description: Caldwell Interchange SR99/Ave280 (Visalia) - Replace Bridge Structures and Construct Roundabouts.
Location Description: TULARE COUNTY IN AND NEAR VISALIA FROM 0.6 MILE SOUTH OF AVENUE 280 OVERCROSSING TO 0.7 MILE NORTH OF AVENUE 280 OVERCROSSING
Contractor Name: Granite Construction Company (Karen Cervantes)
Contractor Address: 2716 Granite Court, Fresno, CA 93706
Resident Engineer: Alberto Lopez Structure Rep.: Martin Garcia

Sample Information

DIME Sample ID: 2026-07-22-8
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Vallejo Field Laboratory
Sample Organization Contact: 9166394315
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 07/22/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/27/2026
The quantity of what the sample constitutes: HRC 555 - 2 LOTS
A brief description of the sample: HRC 555 - Lot 1 and 2
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Pacific Steel Group Napa

Material Information

Production or Authorization Testing: Authorization Testing
Rebar Heat Number(s): 3500048055
Head Manufacturer Lot Number(s): HRC555
Rebar Size: #8
Headed Bar Model Name: HRC555
Size of Head: Full Size - 9x
Head Connection Type:
Head Shape: Circular
Rebar Manufacturer: HRC555
Head Manufacturer: HRC555
Head Fabricator: HRC555
Material Standard Code: ASTM A706
Headed Bar Unique ID: 4FG-17-01

Test Results

Test

DIME Test ID: 2026-07-22-8-1
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 08/04/2026
Date Tested: 08/04/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 8
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
1/20.797300092400Ok NeckingWSP
1/20.797343593000Ok NeckingWSP
1/20.797468094500Ok NeckingWSP
1/20.797259091900Ok NeckingWSP
1/20.797388093500Ok NeckingWSP
1/20.797247091700Ok NeckingWSP
1/20.797132090300Ok NeckingWSP
1/20.797083089700Ok NeckingWSP
Temperature 0 f
UTM NA