Print Report | Back to Sample Detail

Sample Record for 2026-07-22-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000682 DEA: 09379104 EFIS: 0919000005 QA Service Level: 1
DIST-CO-RTE-PM: 09-INY-395-91.6/100.8
Work Description: CONSTRUCT HMA, CURB RAMPS, AND ELECTRICAL SYSTEMS.
Location Description: INYO COUNTY AT AND NEAR BIG PINE FROM 0.1 MILE SOUTH OF ELNA ROAD TO SOUTH JUNCTION ROUTE 168
Contractor Name: ROAD AND HIGHWAY BUILDERS, LLC.
Contractor Address: P.O. Box 70846, Reno, N V, 89570
Resident Engineer: Adam Zumstein Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-07-22-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 07/22/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/31/2026
The quantity of what the sample constitutes: 2000
A brief description of the sample: A325 5/8" x 1-3/4" Bolts
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Ameron Poles Oklahoma

Material Information

Rocap Number(s): N/A
Heat Number(s): 1000131757
Nut Mfg. Lot Number(s): N/A
Washer Mfg. Lot Number(s): N/A
Bolt Specification: ASTM A325
Bolt Length(s): 1.75"
Nut Specification: N/A
Washer Specification: N/A
Finish: Galvanized
Diameter/Size: 5/8"
Bolt Mfg. Lot Number: 021026-1CE
Rocap Test Requirement(s): No
Lubricant Requirements(s): No
Washer Inner Diameter(s): Zero

Test Results

Test

DIME Test ID: 2026-07-22-1-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 08/11/2026
Date Tested: 08/03/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 021026-1CB
Mfg. Lot Number no data
Finish Coating ASTM A153 - Hot Dip
Product Markings A325 USA BBC
Size 0.625 in
Bolt Length 1.75 in
Pitch Diameter 0.5760 in
Pitch Diameter 2nd no data in

Test

DIME Test ID: 2026-07-22-1-2
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 08/11/2026
Date Tested: 08/03/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 021026-1CB
Mfg. Lot Number no data
Finish Coating ASTM A153 - Hot Dip
Product Markings A325 USA BBC
Size 0.625 in
Bolt Length 1.75 in
Pitch Diameter 0.5760 in
Pitch Diameter 2nd no data in

Test

DIME Test ID: 2026-07-22-1-3
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 08/11/2026
Date Tested: 08/03/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) 021026-1CB
Mfg. Lot Number no data
Finish Coating ASTM A153 - Hot Dip
Product Markings A325 USA BBC
Size 0.625 in
Bolt Length 1.75 in
Pitch Diameter 0.5765 in
Pitch Diameter 2nd no data in

Test

DIME Test ID: 2026-07-22-1-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/11/2026
Date Tested: 08/11/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 021026-1CB
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size no data in
Bolt Length no data in
Measurement Average 3.4 mils

Test

DIME Test ID: 2026-07-22-1-5
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/11/2026
Date Tested: 08/11/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 021026-1CB
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size no data in
Bolt Length no data in
Measurement Average 3.1 mils

Test

DIME Test ID: 2026-07-22-1-6
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/11/2026
Date Tested: 08/11/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 021026-1CB
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size no data in
Bolt Length no data in
Measurement Average 2.9 mils

Test

DIME Test ID: 2026-07-22-1-7
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 08/11/2026
Date Tested: 08/11/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 2
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
1A021026-1CB0.6253235000TensileKleinfelder
1B021026-1CB0.6253276000TensileKleinfelder
UTM NA
Temperature 0 f