Print Report | Back to Sample Detail

Sample Record for 2026-06-26-57

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 44444 DEA: ASCP EFIS: ASCP QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for Asphalt Supplier Certification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-06-26-57
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Preliminary
Type of Material: Asphalt Binder
Sample Taken Date: 06/26/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/20/2026
The quantity of what the sample constitutes: 1 of 1
A brief description of the sample: Tank 04
From where was the sample collected: Manufacturer
Laboratory sample identification: TK0406262026
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Mojave, CA

Material Information

Performance Grade: PG 70-10
Modified:
Lot number:
Sublot number:
Tank number: 4
Time of sample:
HMA Supplier: N/A
Certified Asphalt Supplier: Pacific Asphalt Distribution - Mojave CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number: TK0406262026
HMA Type: N/A
HMA Supplier Mix ID Number: N/A

Test Results

Test

DIME Test ID: 2026-06-26-57-1
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 08/05/2026
Date Tested: 08/05/2026
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: OG
Test Result Compliance: complies
Additional Comments When Verified:
Phase Original binder
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 12.06 %
Stress Amplitude 0.175 kPa
Phase Angle (δ) (for the 10 cycles) 87.8 degree
Complex Modulus (G*) (for the 10 measurements) 1.450 kPa
Test Temperature (Specimen 1) 70.0 C
Dynamic Shear, G*/sin(δ) 1.45 kPa

Test

DIME Test ID: 2026-06-26-57-2
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 08/05/2026
Date Tested: 08/05/2026
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: RTFO
Test Result Compliance: complies
Additional Comments When Verified:
Phase RTFO residue
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 10.05 %
Stress Amplitude 0.397 kPa
Phase Angle (δ) (for the 10 cycles) 84.7 degree
Complex Modulus (G*) (for the 10 measurements) 3.953 kPa
Test Temperature (Specimen 1) 70.0 C
Dynamic Shear, G*/sin(δ) 3.97 kPa

Test

DIME Test ID: 2026-06-26-57-3
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 08/05/2026
Date Tested: 08/05/2026
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: PAV
Test Result Compliance: complies
Additional Comments When Verified:
Phase PAV residue
Test Plate Diameter 8 mm
Test Gap 2 mm
Test Frequency 10.0 rad/s
Strain Amplitude 1.01 %
Stress Amplitude 44.560 kPa
Phase Angle (δ) (for the 10 cycles) 51.5 degree
Complex Modulus (G*) (for the 10 measurements) 4433.615 kPa
Test Temperature (Specimen 1) 34.0 C
(G*) x sin(δ)= 3470 kPa

Test

DIME Test ID: 2026-06-26-57-4
Test Method: AASHTO T313-2025: Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 08/05/2026
Date Tested: 08/05/2026
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: BBR
Test Result Compliance: complies
Additional Comments When Verified:
Maximum test bath temperature at 240 S 0.0 C
Minimum test bath temperature at 240 S 0.0 C
Estimated Stiffness Modulus 8.0 s 0.000 MPa
Estimated m-value 8.0 s 0.000
Estimated Stiffness Modulus 15.0 s 0.000 MPa
Estimated m-value 15.0 s 0.000
Estimated Stiffness Modulus 30.0 s 0.000 MPa
Estimated m-value 30.0 s 0.000
Estimated Stiffness Modulus 60.0 s 91.832 MPa
Estimated m-value 60.0 s 0.375
Estimated Stiffness Modulus 120.0 s 0.000 MPa
Estimated m-value 120.0 s 0.000
Estimated Stiffness Modulus 240.0 s 0.000 MPa
Estimated m-value 240.0 s 0.000

Test

DIME Test ID: 2026-06-26-57-5
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Verified Date: 08/05/2026
Date Tested: 08/05/2026
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: VISCOSITY @ 135C
Test Result Compliance: complies
Additional Comments When Verified:
Is viscosity reading in cP/Pa-s? Pa-s
Time of test 00:00 HH:MM
Test Temperature 135 C
Speed 50 rpm
Spindle size .463 in
Torque 56 %
Viscosity reading #1 (A) 0.553 Pa-s
Viscosity reading #2 (B) 0.568 Pa-s
Viscosity reading #3 (C) 0.558 Pa-s
Average viscosity 0.56 Pa-s

Test

DIME Test ID: 2026-06-26-57-6
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 08/05/2026
Date Tested: 08/05/2026
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: MASS CHANGE
Test Result Compliance: complies
Additional Comments When Verified:
Is mass change based on one or two containers? Two
Is mass change correction factor needed? Yes
Any material loss from containers during heating process/testing? no data
Mass of container #1 before test (m1i) 203.26 grams
Mass of container #2 before test (m2i) 207.898 grams
Mass of container #1 after test (m1f) 203.103 grams
Mass of container #2 after test (m2f) 207.739 grams
Average mass change -0.445 percent
Mass of empty container #1 168.211 grams
Mass of empty container #2 172.823 grams
Mass correction factor 0.006

Test

DIME Test ID: 2026-06-26-57-7
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Verified Date: 08/05/2026
Date Tested: 08/05/2026
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: DUCTILITY
Test Result Compliance: complies
Additional Comments When Verified:
Is a normal test obtainable? Yes
Number of replicates tested One
Ductility of test #1 (D1) 115 cm
Ductility of sample 115 cm