Sample Record for 2026-07-08-79
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 994654 DEA: 07313504 EFIS: 0715000090
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA,VEN-1-37.7/62.9,0.0/0.9
Work Description: REMOVE AND CONSTRUCT BRIDGE AND CULVERTS.
Location Description: LOS ANGELES AND VENTURA COUNTIES AT VARIOUS LOCATIONS FROM 0.4 MILE SOUTH OF TEMESCAL CANYON ROAD TO 0.1 MILE NORTH OF TONGA STREET
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 13170 TELFAIR AVENUE, SYLMAR, CA 91342
Resident Engineer: Hakim Sheikh Structure Rep.: Aziz Maghsoudloo
Sample Information
DIME Sample ID: 2026-07-08-79
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (213) 505-4213
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 07/08/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/20/2026
The quantity of what the sample constitutes: X
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Bridge Rubber Bearing
Material Information
Mfg. Lot Number(s): 2527-4
Material/Compound/Elastomer ID: NA
Samples Representing: 3
Description (size): 1.15" x 8" x 12"
Comments:
Description (Number of Shims): 2
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Bridge Rubber Bearing
Batch Number: 157119
Test Results
Test
DIME Test ID: 2026-07-08-79-1
Test Method: ASTM D2240-15r21: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 08/06/2026
Date Tested: 08/06/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Temperature
|
0 f
|
|
Humidity
|
0 %
|
|
Reading #1
|
54
|
|
Reading #2
|
55
|
|
Reading #3
|
54
|
|
Reading #4
|
52
|
|
Reading #5
|
54
|
|
Mean
|
54.2
|
Test
DIME Test ID: 2026-07-08-79-2
Test Method: ASTM D412-16r21: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 08/06/2026
Date Tested: 08/06/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of specimens tested
|
5
|
|
Unit of the Ultimate Tensile Values
|
psi
|
|
UTM
|
NA
|
|
Humidity
|
0 %
|
|
Temperature
|
0 f
|
|
Sample 1 Median Thickness
|
0.069 in
|
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
|
Sample 1 Ultimate Tensile
|
2275 psi
|
|
Sample 1 Elongation (350% Min)
|
Pass
|
|
Sample 2 Median Thickness
|
0.072 in
|
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
|
Sample 2 Ultimate Tensile
|
2052 psi
|
|
Sample 2 Elongation (350% Min)
|
Pass
|
|
Sample 3 Median Thickness
|
0.071 in
|
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
|
Sample 3 Ultimate Tensile
|
2337 psi
|
|
Sample 3 Elongation (350% Min)
|
Pass
|
|
Sample 4 Median Thickness
|
0.071 in
|
|
Sample 4 Thickness all Within 0.003 inch?
|
Yes
|
|
Sample 4 Ultimate Tensile
|
2244 psi
|
|
Sample 4 Elongation (350% Min)
|
Pass
|
|
Sample 5 Median Thickness
|
0.074 in
|
|
Sample 5 Thickness all Within 0.003 inch?
|
Yes
|
|
Sample 5 Ultimate Tensile
|
2262 psi
|
|
Sample 5 Elongation (350% Min)
|
Pass
|
|
Median of the Ultimate Tensile Values
|
2262 psi
|
Test
DIME Test ID: 2026-07-08-79-3
Test Method: ASTM D624-00r20: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 08/06/2026
Date Tested: 08/06/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of specimens tested
|
3
|
|
UTM
|
NA
|
|
Humidity
|
0 %
|
|
Temperature
|
0 f
|
|
Sample 1 Median Thickness
|
0.069 in
|
|
Sample 1 Tear Strength
|
234 lb/in
|
|
Sample 2 Median Thickness
|
0.083 in
|
|
Sample 2 Tear Strength
|
238 lb/in
|
|
Sample 3 Median Thickness
|
0.073 in
|
|
Sample 3 Tear Strength
|
232 lb/in
|
|
Median of the Tear Strength Values
|
234 lb/in
|
Test
DIME Test ID: 2026-07-08-79-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 08/06/2026
Date Tested: 08/06/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: