Print Report | Back to Sample Detail

Sample Record for 2026-07-08-79

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994654 DEA: 07313504 EFIS: 0715000090 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA,VEN-1-37.7/62.9,0.0/0.9
Work Description: REMOVE AND CONSTRUCT BRIDGE AND CULVERTS.
Location Description: LOS ANGELES AND VENTURA COUNTIES AT VARIOUS LOCATIONS FROM 0.4 MILE SOUTH OF TEMESCAL CANYON ROAD TO 0.1 MILE NORTH OF TONGA STREET
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 13170 TELFAIR AVENUE, SYLMAR, CA 91342
Resident Engineer: Hakim Sheikh Structure Rep.: Aziz Maghsoudloo

Sample Information

DIME Sample ID: 2026-07-08-79
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (213) 505-4213
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 07/08/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/20/2026
The quantity of what the sample constitutes: X
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Bridge Rubber Bearing

Material Information

Mfg. Lot Number(s): 2527-4
Material/Compound/Elastomer ID: NA
Samples Representing: 3
Description (size): 1.15" x 8" x 12"
Comments:
Description (Number of Shims): 2
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Bridge Rubber Bearing
Batch Number: 157119

Test Results

Test

DIME Test ID: 2026-07-08-79-1
Test Method: ASTM D2240-15r21: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 08/06/2026
Date Tested: 08/06/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 0 f
Humidity 0 %
Reading #1 54
Reading #2 55
Reading #3 54
Reading #4 52
Reading #5 54
Mean 54.2

Test

DIME Test ID: 2026-07-08-79-2
Test Method: ASTM D412-16r21: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 08/06/2026
Date Tested: 08/06/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested 5
Unit of the Ultimate Tensile Values psi
UTM NA
Humidity 0 %
Temperature 0 f
Sample 1 Median Thickness 0.069 in
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 2275 psi
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.072 in
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 2052 psi
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.071 in
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 2337 psi
Sample 3 Elongation (350% Min) Pass
Sample 4 Median Thickness 0.071 in
Sample 4 Thickness all Within 0.003 inch? Yes
Sample 4 Ultimate Tensile 2244 psi
Sample 4 Elongation (350% Min) Pass
Sample 5 Median Thickness 0.074 in
Sample 5 Thickness all Within 0.003 inch? Yes
Sample 5 Ultimate Tensile 2262 psi
Sample 5 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 2262 psi

Test

DIME Test ID: 2026-07-08-79-3
Test Method: ASTM D624-00r20: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 08/06/2026
Date Tested: 08/06/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested 3
UTM NA
Humidity 0 %
Temperature 0 f
Sample 1 Median Thickness 0.069 in
Sample 1 Tear Strength 234 lb/in
Sample 2 Median Thickness 0.083 in
Sample 2 Tear Strength 238 lb/in
Sample 3 Median Thickness 0.073 in
Sample 3 Tear Strength 232 lb/in
Median of the Tear Strength Values 234 lb/in

Test

DIME Test ID: 2026-07-08-79-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 08/06/2026
Date Tested: 08/06/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Result Pass