Print Report | Back to Sample Detail

Sample Record for 2026-06-10-99

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215734 DEA: 024H0104 EFIS: 0218000068 QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-70-78.3/90.3
Work Description: REPLACE AC SURFACING, PLACE HMA AND THERMOPLASTIC TRAFFIC STRIPING.
Location Description: PLUMAS COUNTY NEAR PORTOLA FROM 0.4 MILE WEST OF BIG GRIZZLY CREEK BRIDGE TO 0.8 MILE WEST OF SUMMIT SCHOOL DRIVE
Contractor Name: HAT CREEK CONSTRUCTION & MATERIALS, INC.
Contractor Address: 243339 Hwy 89, N Burney, CA 96013
Resident Engineer: Mike Zdenek Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-06-10-99
TL Number from the TL Form: 036639
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/10/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/12/2026
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 12 boxes of Lime Treated 3/4-inch Type A HMA (eq. PG 64-28)
From where was the sample collected: Manufacturer
Laboratory sample identification: D80227
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Hat Creek Construction and Materials – Ward Lake Plant (Litchfield, CA)

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: JMF2614002
Binder content (%): 5.7
Virgin binder PG:
Design binder PG: PG 64-28
Binder Supplier: Western Emulsions (White City, OR)
RAP content (%): 22
WMA Additives: No
Antistrip type: 1.0% Lime

Test Results

Test

DIME Test ID: 2026-06-10-99-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/23/2026
Date Tested: 06/30/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pb=5.76%
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3047.1 g
Mass of the specimen and specimen basket assembly prior to ignition 5052.3 g
Mass of HMA Sample prior to ignition 2005.2 g
Corrected Asphalt Binder Content 5.76 %
Mass Loss 133.8 g
Mass of aggregate remaining after ignition 1871.4 g
Correction Factor (Percent by mass of HMA Specimen) 0.76 %
Moisture Content no data0 %
Temperature Compensation Factor 0.15 %
Test Temperature 538 C

Test

DIME Test ID: 2026-06-10-99-2
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 07/23/2026
Date Tested: 07/01/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Is an aggregate correction factor used? Yes
Aggregate correction factor for the 2 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1 1/2 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1 in. sieve (% passing) no data0 %
Aggregate correction factor for the 3/4 in. sieve (% passing) 0.5 %
Aggregate correction factor for the 1/2 in. sieve (% passing) -1.6 %
Aggregate correction factor for the 3/8 in. sieve (% passing) -0.8 %
Aggregate correction factor for the #4 sieve (% passing) -0.4 %
Aggregate correction factor for the #8 sieve (% passing) -0.1 %
Aggregate correction factor for the #16 sieve (% passing) 0.4 %
Aggregate correction factor for the #30 sieve (% passing) 0.3 %
Aggregate correction factor for the #50 sieve (% passing) 0.2 %
Aggregate correction factor for the #100 sieve (% passing) no data0 %
Aggregate correction factor for the #200 sieve (% passing) -0.1 %
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 101 %
Cumulative percent passing the 1/2 in. sieve 87 %
Cumulative percent passing the 3/8 in. sieve 76 %
Cumulative percent passing the #4 sieve 49 %
Cumulative percent passing the #8 sieve 32 %
Cumulative percent passing the #16 sieve 22 %
Cumulative percent passing the #30 sieve 16 %
Cumulative percent passing the #50 sieve 11 %
Cumulative percent passing the #100 sieve 8 %
Cumulative percent passing the #200 sieve 6.1 %

Test

DIME Test ID: 2026-06-10-99-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/23/2026
Date Tested: 06/16/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmm=2.471
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7330.6 grams
Mass of oven-dry sample in air for Sample 1 2627.3 grams
Mass of container filled with the sample and water for Sample 1 8894.7 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.471
Theoretical maximum density at 25°C (77°F) 2463.8 kg/m^3

Test

DIME Test ID: 2026-06-10-99-4
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 07/23/2026
Date Tested: 06/16/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmb=2.359
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity 2.353
Bulk Specific Gravity 2 2.364
Bulk Specific Gravity 3 2.358
Average Bulk Specific Gravity 2.358

Test

DIME Test ID: 2026-06-10-99-5
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 07/23/2026
Date Tested: 06/16/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pₐ=4.6%
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 4.8 %
Percent Air Voids 2 4.3 %
Percent Air Voids 3 4.6 %
Average Percent Air Voids 4.6 %

Test

DIME Test ID: 2026-06-10-99-6
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 07/23/2026
Date Tested: 06/24/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: S₁=127psi, S₂=115psi, TSR=91%
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? SI Units
Average Dry Tensile Strength 127 psi
Average Wet Tensile Strength 115 psi
Tensile Strength Ratio 0.91

Test

DIME Test ID: 2026-06-10-99-7
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 07/23/2026
Date Tested: 06/18/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Rut@N₁₅₀₀₀=0.1in., Nf>15000, SIP>15000
Test Result Compliance: complies
Additional Comments When Verified:
Specimen Preparation Method PMLC
Test Temperature 122 F
Air Void Content for specimen A-1 7.1 %
Air Void Content for specimen A-2 7.5 %
Air Void Content for specimen B-1 7.3 %
Air Void Content for specimen B-2 7.3 %
Stripping Inflection Point (Wheel A) >15000
Stripping Inflection Point (Wheel B) >15000
Maximum impression at 5000 passes (left wheel) 1.85 mm
Maximum impression at 5000 passes (right wheel) 1.77 mm
Average impression at 5000 passes (left/right avg) 1.81 mm
Maximum impression at 10000 passes (left wheel) 2.2 mm
Maximum impression at 10000 passes (right wheel) 1.99 mm
Average impression at 10000 passes (left/right avg) 2.1 mm
Maximum impression at 15000 passes (left wheel) 2.43 mm
Maximum impression at 15000 passes (right wheel) 2.29 mm
Average impression at 15000 passes (left/right avg) 2.36 mm
Average impression at 20000 passes (left/right avg) no data
Average impression at 25000 passes (left/right avg) no data