Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1001213 DEA: 11431644 EFIS: 1122000232
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-78-N17.7
Work Description: Cold plane, RHMA overlay, Concrete Barriers, Landscape and Electrical.
Location Description: IN SAN DIEGO COUNTY FROM ROUTE 78/5 SEPARATION TO 0.3 MILE EAST OF ESCONDIDO BOULEVARD UNDERCROSSING.
Contractor Name: Skanska USA Civil West
Contractor Address: 1995 Agua Mansa Rd., Riverside, CA 92509
Resident Engineer: Yong Pak Structure Rep.: Carlos Lopez
DIME Sample ID: 2026-07-09-87
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/09/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/10/2026
The quantity of what the sample constitutes: 4 boxes
A brief description of the sample: Plant Sample
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RJ Noble Corona
HMA Type: RHMA-G
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 49R003ARSPW
Binder content (%): 7.5
Virgin binder PG: PG 64-16
Design binder PG: PG 64-16
Binder Supplier: World Oil
RAP content (%): 0
WMA Additives: Yes
Antistrip type:
DIME Test ID: 2026-07-09-87-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/23/2026
Date Tested: 07/22/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: complies
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4047 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
6128.8 g
|
|
Mass of HMA Sample prior to ignition
|
2081.8 g
|
|
Corrected Asphalt Binder Content
|
7.72 %
|
|
Mass Loss
|
170.6 g
|
|
Mass of aggregate remaining after ignition
|
1911.2 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.47 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2026-07-09-87-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/23/2026
Date Tested: 07/22/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: complies
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7475.6 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2577.9 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8989.4 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.423
|
|
Theoretical maximum density at 25°C (77°F)
|
2416 kg/m^3
|
DIME Test ID: 2026-07-09-87-3
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 08/10/2026
Date Tested: 08/03/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target < 12.7 mm - Tested an Avg of 2.55 mm
Test Result Compliance: complies
Additional Comments When Verified:
|
Specimen Preparation Method
|
PMLC
|
|
Test Temperature
|
122 F
|
|
Air Void Content for specimen A-1
|
6.4 %
|
|
Air Void Content for specimen A-2
|
6.3 %
|
|
Air Void Content for specimen B-1
|
6.2 %
|
|
Air Void Content for specimen B-2
|
6.3 %
|
|
Stripping Inflection Point (Wheel A)
|
>20000
|
|
Stripping Inflection Point (Wheel B)
|
>20000
|
|
Maximum impression at 5000 passes (left wheel)
|
1.88 mm
|
|
Maximum impression at 5000 passes (right wheel)
|
1.55 mm
|
|
Average impression at 5000 passes (left/right avg)
|
1.71 mm
|
|
Maximum impression at 10000 passes (left wheel)
|
2.26 mm
|
|
Maximum impression at 10000 passes (right wheel)
|
1.84 mm
|
|
Average impression at 10000 passes (left/right avg)
|
2.05 mm
|
|
Maximum impression at 15000 passes (left wheel)
|
2.59 mm
|
|
Maximum impression at 15000 passes (right wheel)
|
2.09 mm
|
|
Average impression at 15000 passes (left/right avg)
|
2.34 mm
|
|
Maximum impression at 20000 passes (left wheel)
|
2.8 mm
|
|
Maximum impression at 20000 passes (right wheel)
|
2.29 mm
|
|
Average impression at 20000 passes (left/right avg)
|
2.55 mm
|
|
Average impression at 25000 passes (left/right avg)
|
no data
|