Project Information

Project ID: 994675 DEA: 07390204 EFIS: 0722000334 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-47-0.4 / 2.1
Work Description: Bridge deck replacement with lightweight precast deck panels ultra high performance concrete. Also includes: replacement of seismic sensors, upgrades to median barrier, railings, fences and guard rails. New finger joints.
Location Description: RTE 47 between Terminal Island and San Pedro PM 0.4/2.1
Contractor Name: Skanska
Contractor Address: 1995 Agua Mansa Rd, Riverside, CA 92509
Resident Engineer: Sam Gallardo Structure Rep.: Sami Deeb

Sample Information

DIME Sample ID: 2026-07-17-9
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 07/17/2026
Date that the sample was received by the laboratory/organization performing the testing: 12/22/2025
The quantity of what the sample constitutes: 3 samples of two strands each
A brief description of the sample: 6/10" x 270 KSI PT Strand
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire

Material Information

Comments:
Reel/Coil/Pack Number(s): S381076-9, S381092-9, S381109-9
Number of Coils:
Group Number:
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0513526, S0253291, S0253980
Mfg. Lot Number(s): S381212-2, S381214-7, S381267-8
Manufacturer(s): Sumiden Wire

Test Results

Test

DIME Test ID: 2026-07-17-9-2
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 09/24/2026
Date Tested: 09/24/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (213) 505-4213
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 6
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0513526S381212-20.217630105709000007.3RMA
S0513526S381212-20.217586305482000007.3RMA
S0253291S381214-70.217589805699000007.4RMA
S0253291S381214-7.0217615005496000007.4RMA
S0253980S381267-80.217594605553000006.0RMA
S0253980S381267-80.217601505301000007.3RMA
UTM NA
Temperature 0 f
Extensometers NA