Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993333 DEA: 04264724 EFIS: 0419000068
QA Service Level: 1
DIST-CO-RTE-PM: 04-MRN-101-R20.8/27.1
Work Description: CIP BRIDGES, CONSTRUCT ROADWAY, RETAINING WALLS AND MODIFY ELECTRICAL.
Location Description: MARIN COUNTY IN AND NEAR NOVATO FROM 0.1 MILE SOUTH OF FRANKLIN AVENUE OVERHEAD TO 0.5 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE
Contractor Name: GHILOTTI CONSTRUCTION CO. INC. (RILEY GENAZZI & JOSH SERAFINO)
Contractor Address: 246 GHILOTTI AVE., SANTA ROSA, CA 95407
Resident Engineer: Fabio La Serna Structure Rep.: Jeremy Light
DIME Sample ID: 2026-07-10-40
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Richmond Field Laboratory
Sample Organization Contact: (510) 385-7413
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/10/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/10/2026
The quantity of what the sample constitutes: HMA
A brief description of the sample: 1/2 RHMA-O
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Dutra Materials Richmond
DIME Test ID: 2026-07-10-40-1
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/16/2026
Date Tested: 07/10/2026
Submitted By Organization: CT D04 - Richmond Field Laboratory
Organization Address: 3401 Regatta Blvd.,
Organization City: Richmond
Organization State: CA
Organization Zipcode: 94804
Organization Email: ignacio.arechiga@dot.ca.gov
Organization Phone: (510) 385-7413
General Comments for this Test: L1-SL7 #1
Test Result Compliance: does not comply
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Corrected Asphalt Binder Content
|
8.04 %
|
|
Mass of HMA Sample prior to ignition
|
1640.9 g
|
|
Mass Loss
|
140.9 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.36 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.18 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2026-07-10-40-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/16/2026
Date Tested: 07/10/2026
Submitted By Organization: CT D04 - Richmond Field Laboratory
Organization Address: 3401 Regatta Blvd.,
Organization City: Richmond
Organization State: CA
Organization Zipcode: 94804
Organization Email: ignacio.arechiga@dot.ca.gov
Organization Phone: (510) 385-7413
General Comments for this Test: L1-SL7 #2
Test Result Compliance: does not comply
Additional Comments When Verified:
|
What temperature unit is used?
|
Fahrenheit
|
|
Test procedure used?
|
Method A
|
|
Mass of HMA Sample prior to ignition
|
1662.3 g
|
|
Corrected Asphalt Binder Content
|
7.96 %
|
|
Mass Loss
|
141.3 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.36 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.18 %
|
|
Test Temperature
|
538 F
|
DIME Test ID: 2026-07-10-40-3
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/16/2026
Date Tested: 07/10/2026
Submitted By Organization: CT D04 - Richmond Field Laboratory
Organization Address: 3401 Regatta Blvd.,
Organization City: Richmond
Organization State: CA
Organization Zipcode: 94804
Organization Email: ignacio.arechiga@dot.ca.gov
Organization Phone: (510) 385-7413
General Comments for this Test: L1-SL8
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Corrected Asphalt Binder Content
|
7.51 %
|
|
Mass of HMA Sample prior to ignition
|
1635.5 g
|
|
Mass Loss
|
131.7 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.36 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.18 %
|
|
Test Temperature
|
538 C
|