Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993331 DEA: 023H6904 EFIS: 0218000010
QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-89-30/R42.1
Work Description: ALMANOR WEST REHAB - ROADWAY REHABILITATION
Location Description: IN PLUMAS COUNTY NEAR CANYON DAM FROM LAKE ALMANOR SPILLWAY TO ROUTE 36.
Contractor Name: DIG IT CONSTRUCTION, INC.
Contractor Address: Unknown
Resident Engineer: Sergio Mendoza Structure Rep.: Unknown
DIME Sample ID: 2026-07-07-89
TL Number from the TL Form: 896859
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Production Start-Up
Type of Material: Reclaimed Asphalt Pavement
Sample Taken Date: 07/07/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/08/2026
The quantity of what the sample constitutes: Production Start Up Evaluation
A brief description of the sample: 2 bags of RAP
From where was the sample collected: Manufacturer
Laboratory sample identification: D80265B
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Dig It Chester
DIME Test ID: 2026-07-07-89-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/16/2026
Date Tested: 07/13/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pbr(uncorrected)=6.76%
Pbr≈6.03%
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3161.5 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
4775.1 g
|
|
Mass of HMA Sample prior to ignition
|
1613.6 g
|
|
Corrected Asphalt Binder Content
|
6.76 %
|
|
Mass Loss
|
112.1 g
|
|
Mass of aggregate remaining after ignition
|
1501.5 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data0 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.19 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2026-07-07-89-2
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 07/16/2026
Date Tested: 07/14/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Is an aggregate correction factor used?
|
Yes
|
|
Aggregate correction factor for the 2 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1 1/2 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 3/4 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1/2 in. sieve (% passing)
|
0.2 %
|
|
Aggregate correction factor for the 3/8 in. sieve (% passing)
|
0.9 %
|
|
Aggregate correction factor for the #4 sieve (% passing)
|
4.1 %
|
|
Aggregate correction factor for the #8 sieve (% passing)
|
2.7 %
|
|
Aggregate correction factor for the #16 sieve (% passing)
|
1.4 %
|
|
Aggregate correction factor for the #30 sieve (% passing)
|
0.8 %
|
|
Aggregate correction factor for the #50 sieve (% passing)
|
0.1 %
|
|
Aggregate correction factor for the #100 sieve (% passing)
|
-0.3 %
|
|
Aggregate correction factor for the #200 sieve (% passing)
|
-0.3 %
|
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
|
Cumulative percent passing the 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/8 in. sieve
|
100 %
|
|
Cumulative percent passing the #4 sieve
|
85 %
|
|
Cumulative percent passing the #8 sieve
|
64 %
|
|
Cumulative percent passing the #16 sieve
|
47 %
|
|
Cumulative percent passing the #30 sieve
|
34 %
|
|
Cumulative percent passing the #50 sieve
|
24 %
|
|
Cumulative percent passing the #100 sieve
|
16 %
|
|
Cumulative percent passing the #200 sieve
|
12 %
|
DIME Test ID: 2026-07-07-89-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/16/2026
Date Tested: 07/10/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmmr=2.481, Gser≈2.758
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7330.6 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1544.7 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8252.8 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.481
|
|
Theoretical maximum density at 25°C (77°F)
|
2473.8 kg/m^3
|