Sample Record for 2026-07-14-50

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994415 DEA: 120R3114 EFIS: 1220000021 QA Service Level: 1
DIST-CO-RTE-PM: 12-LA,ORA-91-R20.6/R20.7,R0.0/4.8
Work Description: PLACE JPCP (RSC) AND RHMA, AND MODIFY ELECTRICAL SYSTEMS.
Location Description: LOS ANGELES AND ORANGE COUNTIES FROM 0.1 MILE WEST OF THE LOS ANGLES COUNTY LINE IN CERRITOS TO 0.1 MILE EAST OF ACACIA STREET UNDERCROSSING IN ANAHEIM
Contractor Name: BEADOR CONSTRUCTION COMPANY, INC.
Contractor Address: 2900 Bristol Street, Suite D204, Costa Mesa, CA 92626
Resident Engineer: Bill Gilchrist Structure Rep.: Mahesh Kapoor

Sample Information

DIME Sample ID: 2026-07-14-50
TL Number from the TL Form:
Sample Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Sample Organization Contact: 9492798846
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/14/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/10/2026
The quantity of what the sample constitutes: 6
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 26-0149
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Unknown

Material Information

The concrete mix design number: 1614705
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: Unknown
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Discharge from concrete truck into wheelbarrow.
Where the material sample would have been placed if not sampled: Rt. 91 RW 2, Footing
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2026-07-14-50-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 07/15/2026
Date Tested: 07/14/2026
Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Organization Address: 19601 Beach Boulevard,
Organization City: Huntington Beach
Organization State: CA
Organization Zipcode: 92648
Organization Email: frank.mai@dot.ca.gov
Organization Phone: (949) 279-8846
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4.01 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.63 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 3560 psi
Maximum load on cylinder 1 43910 lb
Maximum load on cylinder 2 45740 lb
Maximum load on cylinder 3 44840 lb
Compressive strength of cylinder 1 3476.6 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 3638.8 psi
Compressive strength of cylinder 3 3567.2 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 4 days
Age of specimen in hours no data0 hours