Sample Record for 2026-07-14-34
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1001489 DEA: 120K61U4 EFIS: 1224000096
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-5-21.3/R25.8
Work Description: CONST BRIDGES, RW, SW, OVERLAY, REPLACE SLABS, MODIFY ELECT SYSTEMS.
Location Description: ORANGE COUNTY IN IRVINE FROM ROUTE 5/405 SEPARATION TO YALE AVENUE OVERCROSSING
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: Unknown
Resident Engineer: Reza Jahromi Structure Rep.: Melissa Quintana
Sample Information
DIME Sample ID: 2026-07-14-34
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Stock
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 07/14/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/31/2026
The quantity of what the sample constitutes: 100
A brief description of the sample: 1" x 2-1/4" A325 Hex Bolt
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Universal Industrial Sales
Material Information
Rocap Number(s): N/A
Heat Number(s): 10868330
Nut Mfg. Lot Number(s): N/A
Washer Mfg. Lot Number(s): N/A
Bolt Specification: A325
Bolt Length(s): 2-1/4"
Nut Specification: N/A
Washer Specification: N/A
Finish: Mech. Galvanized
Diameter/Size: 1"
Bolt Mfg. Lot Number: M5830
Rocap Test Requirement(s): 0
Lubricant Requirements(s): 0
Washer Inner Diameter(s): 0
Test Results
Test
DIME Test ID: 2026-07-14-34-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 08/11/2026
Date Tested: 08/03/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
M5830
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM B695 - Mech Galv
|
|
Product Markings
|
A325 SL USA
|
|
Size
|
1 in
|
|
Bolt Length
|
2.25 in
|
|
Pitch Diameter
|
0.9150 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test
DIME Test ID: 2026-07-14-34-2
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 08/11/2026
Date Tested: 08/03/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
M5830
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM B695 - Mech Galv
|
|
Product Markings
|
A325 SL USA
|
|
Size
|
1 in
|
|
Bolt Length
|
2.25 in
|
|
Pitch Diameter
|
0.9195 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test
DIME Test ID: 2026-07-14-34-3
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/11/2026
Date Tested: 08/11/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
M5830
|
|
Finish Coating
|
ASTM B695 - Mech Galv
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.5 mils
|
Test
DIME Test ID: 2026-07-14-34-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/11/2026
Date Tested: 08/11/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
M5830
|
|
Finish Coating
|
ASTM B695 - Mech Galv
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.3 mils
|
Test
DIME Test ID: 2026-07-14-34-5
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 08/11/2026
Date Tested: 08/11/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Bolt Samples
|
1
|
| Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | | 1A | M5830 | 1 | 87400 | 0 | 0 | Tensile | Kleinfelder |
| |
|
UTM
|
NA
|
|
Temperature
|
0 f
|