Print Report | Back to Sample Detail

Sample Record for 2026-07-14-27

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001686 DEA: 11430264 EFIS: 1118000083 COOP: NONE QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-94,188-15.2/65.3,0.0/1.9
Work Description: DRAINAGE RESTORATION, ADA CURB RAMPS & COMPLETE STREET.
Location Description: SAN DIEGO COUNTY ABOUT 6 MILES EAST OF LEMON GROVE ON ROUTE 94 FROM SWEETWATER RIVER BRIDGE TO AVENUE DE ROBLES VERDES NEAR MANZANITA AND ON ROUTE 188 FROM MEXICO BORDER NEAR TECATE TO ROUTE 94.
Contractor Name: LB Civil Construction
Contractor Address: 324 East Valley Parkway, Escondido, CA 92025
Resident Engineer: Daniel Assefa Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-07-14-27
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Vallejo Field Laboratory
Sample Organization Contact: 9166394315
Type of Sample: Quality Assurance
Type of Material: SMTL TM7 - Epoxy Coated Dowels
Sample Taken Date: 07/14/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/17/2026
The quantity of what the sample constitutes: 2
A brief description of the sample: 1 ¼” X 18” FULLY EPOXY COATED PURPLE DOWEL BAR BASKETS (12 BAR 10.2” PAVE)
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: American Highway

Material Information

Dowel Metal Heat Number: 1201069352
Dowel Epoxy Batch Number: CH3005KW
Dowel Coating Specification: ASTM A934
Dowel Size: 1.25 in
Dowel Coating Color: Purple
Dowel Manufacturer: American Highway
Dowel Coater: American Highway
Release Number:
Quality Assurance Code: A934
Rebar Size (#):

Test Results

Test

DIME Test ID: 2026-07-14-27-1
Test Method: ASTM A934-19: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Verified Date: 07/27/2026
Date Tested: 07/27/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Lower spec. limit LSL 7 mils
Upper spec. limit USL 16 mils
Bar # for First Bar 1
Bar # for Second Bar 2
First Bar Mean 10.18
Second Bar Mean 10.24
Total mean value 10.21

Test

DIME Test ID: 2026-07-14-27-2
Test Method: ASTM A934-19: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Holiday Bend)
Verified Date: 07/27/2026
Date Tested: 07/27/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Total Number of Holiday no data0
Total Length 3
Holidays Per Linear Foot of Bar no data0 holiday per ft
Holiday Test Pass/Fail Pass