Project ID: 1000709 DEA: 041Y6904 EFIS: 0423000015 COOP: NONE
QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA,ALA-92-14.4/18.8
Work Description: ALAMEDA & SAN MATEO HAYWARD TRESTLE REPAIR AND HIGH RISE PIER REPAIR.
Location Description: ALAMEDA AND SAN MATEO COUNTIES AT VARIOUS LOCATIONS FROM 7.0 MILES WEST OF TOLL PLAZA TO 0.2 MILE WEST OF TOLL PLAZA
Contractor Name: GOLDEN STATE BRIDGE
Contractor Address: 3701 Mallard Drive, Benicia, CA 94510
Resident Engineer: Randy Miller Structure Rep.: Bettie Geng
DIME Sample ID: 2026-07-10-31
TL Number from the TL Form:
Sample Submitted By Organization: CT SC - 3674 - Oakland
Sample Organization Contact: (510) 719-7463
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/10/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/14/2026
The quantity of what the sample constitutes: 10CY
A brief description of the sample: Ready Mix Concrete
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Rock
The concrete mix design number: 08S905E8SI
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 157753
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: From chute into bucket
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2026-07-10-31-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/10/2026
Date Tested: 08/10/2026
Submitted By Organization: CT HQ - Vallejo Field Laboratory
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
6630 psi
|
|
Maximum load on cylinder 1
|
82150 lb
|
|
Maximum load on cylinder 2
|
84220 lb
|
|
Maximum load on cylinder 3
|
83750 lb
|
|
Compressive strength of cylinder 1
|
6535.4 psi
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Compressive strength of cylinder 2
|
6700.1 psi
|
|
Compressive strength of cylinder 3
|
6662.7 psi
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Type of fracture pattern of cylinder 3
|
3
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
31 days
|
|
Age of specimen in hours
|
no data0 hours
|