Print Report | Back to Sample Detail

Sample Record for 2018-03-27-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212577 DEA: 11408704 EFIS: 1112000017 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-8-9.0/15.3
Work Description: SLAB REPLACEMENT, COLD PLANE, GRIND PAVEMENT AND REPLACE GUARDRAIL.
Location Description: SAN DIEGO COUNTY FROM 0.6 MILE WEST OF LAKE MURRAY BOULEVARD OVERCROSSING IN SAN DIEGO TO JOHNSON AVENUE UNDERCROSSING IN EL CAJON
Contractor Name: FLATIRON WEST, INC.
Contractor Address: 1770 La Costa Meadows Drive, San Marcos, CA 92078
Resident Engineer: John Williamson Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2018-03-27-2
TL Number from the TL Form: C925916
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (213) 505-4213
Type of Sample: Quality Assurance
Type of Material: SMTL TM7 - Epoxy Coated Rebar
Sample Taken Date: 03/27/2018
Date that the sample was received by the laboratory/organization performing the testing: 03/29/2018
The quantity of what the sample constitutes: 2
A brief description of the sample: Green Epoxy Coated Dowel Basket
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Dayton Superior

Material Information

Rebar Heat Number(s): NA
Rebar Epoxy Batch Number(s):
Rebar Coating Specification: ASTM A775
Rebar Size (#): 6
Rebar Coating Color: Green
Rebar Manufacturer: Unknown
Rebar Coater: Unknown
Rebar Powder Manufacturer: Unknown
Release Number: 1387825-2
Quality Assurance Code: Unknown

Test Results

Test

DIME Test ID: 2018-03-27-2-1
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Verified Date: 04/03/2018
Date Tested: 03/30/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean 12.87
Second Bar Mean 10.7
Lower spec. limit LSL 7
Upper spec. limit USL 16
Bar # for First Bar no data
Bar # for Second Bar no data
Total mean value 11.78
Total number of values less than LSL no data
Total number of values greater than USL no data

Test

DIME Test ID: 2018-03-27-2-2
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Verified Date: 04/03/2018
Date Tested: 03/30/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday no data0
Total Length 2.6
Holidays Per Linear Foot of Bar no data0 holiday per ft
Holiday Test Pass/Fail Pass
Bend Test Pass/Fail Pass