Print Report | Back to Sample Detail

Sample Record for 2026-07-06-45

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000481 DEA: 081C07U4 EFIS: 0824000168 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-74-27.5/34.3
Work Description: RUBBERIZED HMA, FIBER OPTIC CABLE SYSTEMS, AND COLD PLANE AC PAVEMENT.
Location Description: RIVERSIDE COUNTY AT AND NEAR ROMOLAND AND HOMELAND FROM BONNIE DRIVE TO WINCHESTER ROAD
Contractor Name: GRIFFITH COMPANY
Contractor Address: 12200 Bloomfield Avenue, Santa Fe Springs, CA 90670
Resident Engineer: Omar Sanchez Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-07-06-45
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/06/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/08/2026
The quantity of what the sample constitutes: 263.13
A brief description of the sample: 3/4 RHMA-G
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Mariatta - Lake Elsinore

Material Information

HMA Type: RHMA-G
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number:
Binder content (%): 0.0
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test

DIME Test ID: 2026-07-06-45-1
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/10/2026
Date Tested: 07/10/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Corrected Asphalt Binder Content 7.55 %
Mass of HMA Sample prior to ignition 2170 g
Mass Loss 178.2 g
Correction Factor (Percent by mass of HMA Specimen) 0.52 %
Moisture Content no data0 %
Temperature Compensation Factor 0.14 %
Test Temperature 538 C