Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994675 DEA: 07390204 EFIS: 0722000334
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-47-0.4 / 2.1
Work Description: Bridge deck replacement with lightweight precast deck panels ultra high performance concrete. Also includes: replacement of seismic sensors, upgrades to median barrier, railings, fences and guard rails. New finger joints.
Location Description: RTE 47 between Terminal Island and San Pedro PM 0.4/2.1
Contractor Name: Skanska
Contractor Address: 1995 Agua Mansa Rd, Riverside, CA 92509
Resident Engineer: Sam Gallardo Structure Rep.: Sami Deeb
DIME Sample ID: 2026-07-07-55
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (213) 505-4213
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 07/07/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/09/2026
The quantity of what the sample constitutes: 1 Pack
A brief description of the sample: 0.600" PT Strand
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire
Comments:
Reel/Coil/Pack Number(s):
Number of Coils:
Group Number:
Strand Diameter:
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0253777
Mfg. Lot Number(s): S337149-6
Manufacturer(s): Sumiden Wire
DIME Test ID: 2026-07-07-55-1
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 09/24/2026
Date Tested: 09/24/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (213) 505-4213
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
1
|
| Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | | S0253777 | S337149-6 | 0.217 | 61960 | 56970 | 0000 | 8.0 | RMA |
| |
|
UTM
|
NA
|
|
Temperature
|
0 f
|
|
Extensometers
|
NA
|