Sample Record for 2026-07-01-37
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1000759 DEA: 074X9704 EFIS: 0716000335
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA,-1-42.4
Work Description: CONSTRUCT DRILLED HOLE AND DRILLED HOLE (ROCK SOCKET).
Location Description: LOS ANGELES COUNTY IN MALIBU AT 0.1 MILE SOUTH OF BIG ROCK DRIVE
Contractor Name: BEADOR CONSTRUCTION COMPANY, INC.
Contractor Address: 2900 Bristol Street, Suite D204, Costa Mesa, CA 92626
Resident Engineer: Elizabeth Martinez Structure Rep.: Frank Lotfi
Sample Information
DIME Sample ID: 2026-07-01-37
TL Number from the TL Form: 070126
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 07/01/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/02/2026
The quantity of what the sample constitutes: 130 CY
A brief description of the sample: 4X8 PCC cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 26-207
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Associate Ready Mix
Material Information
The concrete mix design number: SL4KCNIMK
The truck number from where the sample was collected: 80748
The batch plant ticket number from where the sample was collected: 7782442
Concrete batch plant: Associated Ready Mix Concrete
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: truck chute
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test
DIME Test ID: 2026-07-01-37-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 07/08/2026
Date Tested: 07/08/2026
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.01 in
|
|
Average diameter of cylinder 2
|
4.02 in
|
|
Average diameter of cylinder 3
|
4.02 in
|
|
Cross sectional area of cylinder 1
|
12.63 in^2
|
|
Cross sectional area of cylinder 2
|
12.69 in^2
|
|
Cross sectional area of cylinder 3
|
12.69 in^2
|
|
Compressive strength (to nearest 10 psi)
|
6020 psi
|
|
Maximum load on cylinder 1
|
76569 lb
|
|
Maximum load on cylinder 2
|
78558 lb
|
|
Maximum load on cylinder 3
|
73738 lb
|
|
Compressive strength of cylinder 1
|
6062.5 psi
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Compressive strength of cylinder 2
|
6190.5 psi
|
|
Compressive strength of cylinder 3
|
5810.7 psi
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Type of fracture pattern of cylinder 3
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
7 days
|
|
Age of specimen in hours
|
no data0 hours
|