Print Report | Back to Sample Detail

Sample Record for 2026-07-08-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001194 DEA: 051H4404 EFIS: 0516000074 QA Service Level: 1
DIST-CO-RTE-PM: 05-SB,SLO-1-50.3/50.6,0.0/0.3
Work Description: SANTA MARIA RIVER BRIDGE (REPLACE).
Location Description: SANTA BARBARA AND SAN LUIS OBISPO COUNTIES IN AND NEAR GUADALUPE AT SANTA MARIA RIVER BRIDGE
Contractor Name: M.C.M. CONSTRUCTION, INC.
Contractor Address: 6413 32nd Street, North Highlands, Ca 95660
Resident Engineer: Jacob Cooper Structure Rep.: Sal Heredia

Sample Information

DIME Sample ID: 2026-07-08-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 07/08/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/09/2026
The quantity of what the sample constitutes: 12
A brief description of the sample: #7 ASTM A706 Gr. 60 Rebar
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: TNT Rebar

Material Information

Production or Authorization Testing: Authorization Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): 9013707
Hoop Manufacturer Lot Number(s): 1, 5, 10
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: #7
Diameter of Hoop: 3'-6"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: CMC Arizona
Welding Company: TNT Rebar Company
Coating Standards: Uncoated
Weld Type: Flash Welded

Test Results

Test

DIME Test ID: 2026-07-08-2-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 07/17/2026
Date Tested: 07/17/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 12
SampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1170.605915098500ok neckingKleinfelder
2170.6062160104000ok neckingKleinfelder
3170.605848097500ok neckingKleinfelder
4170.605947099000ok neckingKleinfelder
1570.605524092000ok neckingKleinfelder
2570.605511092000ok neckingKleinfelder
3570.605493091500ok neckingKleinfelder
4570.605523092000ok neckingKleinfelder
11070.605786096500ok neckingKleinfelder
21070.605685095000ok neckingKleinfelder
31070.605583093000ok neckingKleinfelder
41070.605877098000ok neckingKleinfelder
UTM NA