Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1002077 DEA: 033H5904 EFIS: 0318000017
QA Service Level: 1
DIST-CO-RTE-PM: 03-PLA-80-R26.3/R55.2
Work Description:
Location Description:
Contractor Name: Flatiron Dragados/Teichert
Contractor Address: 555 S Auburn St, Colfax, CA 95713
Resident Engineer: John Ruzic Structure Rep.: Carl Anderson
DIME Sample ID: 2026-06-22-72
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (213) 505-4213
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 06/22/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/07/2026
The quantity of what the sample constitutes: 37
A brief description of the sample: Bearing Pad w/ Shims
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber
Mfg. Lot Number(s): 27837-1
Material/Compound/Elastomer ID: NA
Samples Representing: 37
Description (size): 2.88" X 14" X 14"
Comments:
Description (Number of Shims): 5
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: NA
DIME Test ID: 2026-06-22-72-1
Test Method: ASTM D2240-15r21: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 08/06/2026
Date Tested: 08/06/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Temperature
|
0 f
|
|
Humidity
|
0 %
|
|
Reading #1
|
49
|
|
Reading #2
|
49
|
|
Reading #3
|
50
|
|
Reading #4
|
51
|
|
Reading #5
|
51
|
|
Mean
|
50.3
|
DIME Test ID: 2026-06-22-72-2
Test Method: ASTM D412-16r21: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 08/06/2026
Date Tested: 08/06/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of specimens tested
|
3
|
|
Unit of the Ultimate Tensile Values
|
psi
|
|
UTM
|
NA
|
|
Humidity
|
0 %
|
|
Temperature
|
0 f
|
|
Sample 1 Median Thickness
|
0.072 in
|
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
|
Sample 1 Ultimate Tensile
|
2731 psi
|
|
Sample 1 Elongation (350% Min)
|
Pass
|
|
Sample 2 Median Thickness
|
0.068 in
|
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
|
Sample 2 Ultimate Tensile
|
2511 psi
|
|
Sample 2 Elongation (350% Min)
|
Pass
|
|
Sample 3 Median Thickness
|
0.067 in
|
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
|
Sample 3 Ultimate Tensile
|
2617 psi
|
|
Sample 3 Elongation (350% Min)
|
Pass
|
|
Median of the Ultimate Tensile Values
|
2617 psi
|
DIME Test ID: 2026-06-22-72-3
Test Method: ASTM D624-00r20: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 08/06/2026
Date Tested: 08/06/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of specimens tested
|
3
|
|
UTM
|
NA
|
|
Humidity
|
0 %
|
|
Temperature
|
0 f
|
|
Sample 1 Median Thickness
|
0.074 in
|
|
Sample 1 Tear Strength
|
211 lb/in
|
|
Sample 2 Median Thickness
|
0.076 in
|
|
Sample 2 Tear Strength
|
202 lb/in
|
|
Sample 3 Median Thickness
|
0.067 in
|
|
Sample 3 Tear Strength
|
216 lb/in
|
|
Median of the Tear Strength Values
|
211 lb/in
|
DIME Test ID: 2026-06-22-72-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 08/06/2026
Date Tested: 08/06/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: