Print Report | Back to Sample Detail

Sample Record for 2026-06-22-70

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001248 DEA: 120K93U4 EFIS: 1224000084 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-57,91-13.9/16.1,4.8/6.6
Work Description: CONST BRIDGES, RW, SW, PAVEMENT, DRAINAGE AND ELECTRICAL SYSTEMS.
Location Description: ANAHEIM AND PLACENTIA ON ROUTE 57 FROM WAGNER AVENUE OVERCROSSING TO 0.2 MILE NORTH OF MIRALOMA AVENUE OVERCROSSING AND ON ROUTE 91 FROM 0.1 MILE EAST OF ACACIA STREET UNDERCROSSING TO 0.2 MILE EAST OF LA PALMA AVENUE OVERCROSSING
Contractor Name: OHLA USA, INC
Contractor Address: 2550 East Miraloma Way, Suite 200, Anaheim, CA 92806
Resident Engineer: Charlie Nakamoto Structure Rep.: Lance Yamashiro

Sample Information

DIME Sample ID: 2026-06-22-70
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (213) 505-4213
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 06/22/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/07/2026
The quantity of what the sample constitutes: 19
A brief description of the sample: Bearing Pad w/8 14GA Shims
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber

Material Information

Mfg. Lot Number(s): 27509-6
Material/Compound/Elastomer ID: NA
Samples Representing: 19
Description (size): 4.6" X 16" X 24"
Comments:
Description (Number of Shims): 8
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: NA

Test Results

Test

DIME Test ID: 2026-06-22-70-1
Test Method: ASTM D2240-15r21: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 08/31/2026
Date Tested: 08/06/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 0 f
Humidity 0 %
Reading #1 51
Reading #2 52
Reading #3 51
Reading #4 53
Reading #5 52
Mean 52.1

Test

DIME Test ID: 2026-06-22-70-3
Test Method: ASTM D624-00r20: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 08/31/2026
Date Tested: 08/06/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested 3
UTM NA
Humidity 0 %
Temperature 0 f
Sample 1 Median Thickness 0.069 in
Sample 1 Tear Strength 183 lb/in
Sample 2 Median Thickness 0.073 in
Sample 2 Tear Strength 182 lb/in
Sample 3 Median Thickness 0.069 in
Sample 3 Tear Strength 188 lb/in
Median of the Tear Strength Values 183 lb/in

Test

DIME Test ID: 2026-06-22-70-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 08/31/2026
Date Tested: 08/06/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Result Pass

Test

DIME Test ID: 2026-06-22-70-5
Test Method: ASTM D412-16r21: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 08/31/2026
Date Tested: 08/31/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 5
Unit of the Ultimate Tensile Values psi
UTM NA
Humidity 0 %
Temperature 0 f
Sample 1 Median Thickness 0.072 in
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 2362 psi
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.072 in
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 2388 psi
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.082 in
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 2235 psi
Sample 3 Elongation (350% Min) Pass
Sample 4 Median Thickness 0.077 in
Sample 4 Thickness all Within 0.003 inch? Yes
Sample 4 Ultimate Tensile 2374 psi
Sample 4 Elongation (350% Min) Pass
Sample 5 Median Thickness 0.078 in
Sample 5 Thickness all Within 0.003 inch? Yes
Sample 5 Ultimate Tensile 2424 psi
Sample 5 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 2374 psi