Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000501 DEA: 081J6104 EFIS: 0818000102
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-215-40.5/42.7
Work Description: INDIVIDUAL SLAB REPLACEMENT (RSC), RHMA, AND REPLACE BASE.
Location Description: RIVERSIDE COUNTY IN RIVERSIDE FROM 0.8 MILE SOUTH OF ROUTE 60/91 SEPARATION TO 0.4 MILE SOUTH OF MARTIN LUTHER KING BOULEVARD UNDERCROSSING
Contractor Name: FBD VANGUARD CONSTRUCTION, INC.
Contractor Address: 550 Greenville Rd., Livermore, CA
Resident Engineer: Mahfual Alam Structure Rep.: Unknown
DIME Sample ID: 2026-05-15-86
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Sample Organization Contact: 9512323690
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/15/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/10/2026
The quantity of what the sample constitutes: 1 box, 6 cores
A brief description of the sample: RHMA-G SP 3/4"
From where was the sample collected: Job Site
Laboratory sample identification: 3A, 3B, 3C, 4A, 4B, 4C
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: R.J. Noble Co. — Corona
DIME Test ID: 2026-05-15-86-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/06/2026
Date Tested: 05/19/2026
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7339.5 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2549.7 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8861.8 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.482
|
|
Theoretical maximum density at 25°C (77°F)
|
154.5 lb/ft^3
|
DIME Test ID: 2026-05-15-86-2
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 07/06/2026
Date Tested: 06/11/2026
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: 3A, 3B, 3C
Test Result Compliance: complies
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.286
|
|
Bulk Specific Gravity 2
|
2.321
|
|
Bulk Specific Gravity 3
|
2.318
|
|
Average Bulk Specific Gravity
|
2.308
|
DIME Test ID: 2026-05-15-86-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 07/06/2026
Date Tested: 06/11/2026
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: 4A, 4B, 4C
Test Result Compliance: complies
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.322
|
|
Bulk Specific Gravity 2
|
2.323
|
|
Bulk Specific Gravity 3
|
2.304
|
|
Average Bulk Specific Gravity
|