Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000607 DEA: 081K6904 EFIS: 0819000090
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-74-5.7/11.8
Work Description: ROCK EXCAVATION, HMA (TYPE A), RHMA-G, AND CABLE NET DRAPERY SYSTEM.
Location Description: RIVERSIDE COUNTY IN AND NEAR LAKE ELSINORE FROM MONTE VISTA STREET TO GRAND AVENUE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: Unknown
Resident Engineer: Fereydoon Alipanah Structure Rep.: Unknown
DIME Sample ID: 2026-06-27-13
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/27/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/30/2026
The quantity of what the sample constitutes: 1560.40 TONS OUT
A brief description of the sample: 3/4" HMA TYPE A
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta (CCA) Lake Elsinore
DIME Test ID: 2026-06-27-13-1
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/07/2026
Date Tested: 07/03/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Corrected Asphalt Binder Content
|
4.57 %
|
|
Mass of HMA Sample prior to ignition
|
2180.3 g
|
|
Mass Loss
|
118.7 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.74 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.14 %
|
|
Test Temperature
|
538 C
|