Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1001213 DEA: 11431644 EFIS: 1122000232
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-78-N17.7
Work Description: Cold plane, RHMA overlay, Concrete Barriers, Landscape and Electrical.
Location Description: IN SAN DIEGO COUNTY FROM ROUTE 78/5 SEPARATION TO 0.3 MILE EAST OF ESCONDIDO BOULEVARD UNDERCROSSING.
Contractor Name: Skanska USA Civil West
Contractor Address: 1995 Agua Mansa Rd., Riverside, CA 92509
Resident Engineer: Yong Pak Structure Rep.: Carlos Lopez
DIME Sample ID: 2026-06-28-15
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/28/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/29/2026
The quantity of what the sample constitutes: 4 boxes
A brief description of the sample: Normal Production
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RJ Noble Corona
DIME Test ID: 2026-06-28-15-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/10/2026
Date Tested: 07/08/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Target 7.50%, complies
oven 4
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4033.3 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5598.9 g
|
|
Mass of HMA Sample prior to ignition
|
1565.6 g
|
|
Corrected Asphalt Binder Content
|
7.72 %
|
|
Mass Loss
|
127.6 g
|
|
Mass of aggregate remaining after ignition
|
1438 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.43 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|