Print Report | Back to Sample Detail

Sample Record for 2026-06-22-41

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001213 DEA: 11431644 EFIS: 1122000232 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-78-N17.7
Work Description: Cold plane, RHMA overlay, Concrete Barriers, Landscape and Electrical.
Location Description: IN SAN DIEGO COUNTY FROM ROUTE 78/5 SEPARATION TO 0.3 MILE EAST OF ESCONDIDO BOULEVARD UNDERCROSSING.
Contractor Name: Skanska USA Civil West
Contractor Address: 1995 Agua Mansa Rd., Riverside, CA 92509
Resident Engineer: Yong Pak Structure Rep.: Carlos Lopez

Sample Information

DIME Sample ID: 2026-06-22-41
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/22/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/23/2026
The quantity of what the sample constitutes: 4 boxes
A brief description of the sample: Plant Sample
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RJ Noble Corona

Material Information

HMA Type: RHMA-G
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 49R003ARSPW
Binder content (%): 7.5
Virgin binder PG: PG 64-16
Design binder PG: PG 64-16
Binder Supplier: World Oil
RAP content (%): 0
WMA Additives: Yes
Antistrip type:

Test Results

Test

DIME Test ID: 2026-06-22-41-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/06/2026
Date Tested: 07/02/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Target 7.5% Actual 7.89% Oven# 3
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of the specimen basket assembly 3923.7 g
Mass of the specimen and specimen basket assembly prior to ignition 5956.9 g
Mass of HMA Sample prior to ignition 2033.2 g
Corrected Asphalt Binder Content 7.89 %
Mass Loss 172.4 g
Mass of aggregate remaining after ignition 1860.8 g
Correction Factor (Percent by mass of HMA Specimen) 0.59 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 F

Test

DIME Test ID: 2026-06-22-41-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/08/2026
Date Tested: 07/06/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Verify Eddie's RICE of 2.402. Target 2.426. Rice Verified Re-tested at 2.412 Gmm
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7475.6 grams
Mass of oven-dry sample in air for Sample 1 2528 grams
Mass of container filled with the sample and water for Sample 1 8955.6 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.412
Theoretical maximum density at 25°C (77°F) 150.1 lb/ft^3

Test

DIME Test ID: 2026-06-22-41-4
Test Method: CTM 375-February 2012: Determining the Density and Relative Compaction of Data Cores (lab)
Verified Date: 07/09/2026
Date Tested: 07/09/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: COMPLIES
Test Result Compliance: complies
Additional Comments When Verified:
Number of Cores 3
Core ID 6A53
Dry Weight 1071.6 grams
Parrafin Coated Weight 1088 grams
Coated Weight in Water 599.8 grams
Theoretical Maximum Density 2.412
Core 2 ID 6B53
Dry Weight 2 1040.4 grams
Parrafin Coated Weight 2 1055.2 grams
Coated Weight in Water 2 582.8 grams
Core 3 ID 6C53
Dry Weight 3 1036.5 grams
Parrafin Coated Weight 3 1053.5 grams
Coated Weight in Water 3 571.4 grams

Test

DIME Test ID: 2026-06-22-41-5
Test Method: CTM 375-February 2012: Determining the Density and Relative Compaction of Data Cores (lab)
Verified Date: 07/09/2026
Date Tested: 07/09/2026
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: COMPLIES
Test Result Compliance: complies
Additional Comments When Verified:
Number of Cores 3
Core ID 6A54
Dry Weight 1107.2 grams
Parrafin Coated Weight 1127.1 grams
Coated Weight in Water 609.3 grams
Theoretical Maximum Density 2.412
Core 2 ID 6B54
Dry Weight 2 1035.9 grams
Parrafin Coated Weight 2 1058.5 grams
Coated Weight in Water 2 570.1 grams
Core 3 ID 6C54
Dry Weight 3 1069.1 grams
Parrafin Coated Weight 3 1085.9 grams
Coated Weight in Water 3 589.8 grams