Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 44444 DEA: ASCP EFIS: ASCP
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for Asphalt Supplier Certification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2026-06-04-150
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Quality Control
Type of Material: Asphalt Binder
Sample Taken Date: 06/04/2026
Date that the sample was received by the laboratory/organization performing the testing: 07/01/2026
The quantity of what the sample constitutes: 1 of 1
A brief description of the sample: Tank 5
From where was the sample collected: Manufacturer
Laboratory sample identification: 26-0604PNO-5
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Stockton, CA
Performance Grade: PG 64-28
Modified:
Lot number:
Sublot number:
Tank number: 5
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: Pacific Northwest Oil - Stockton CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:
HMA Type:
HMA Supplier Mix ID Number:
DIME Test ID: 2026-06-04-150-1
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/16/2026
Date Tested: 07/16/2026
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: OG
Test Result Compliance: complies
Additional Comments When Verified:
|
Phase
|
Original binder
|
|
Test Gap
|
1 mm
|
|
Test Frequency
|
10.0 rad/s
|
|
Strain Amplitude
|
12.06 %
|
|
Stress Amplitude
|
0.229 kPa
|
|
Phase Angle (δ) (for the 10 cycles)
|
79.4 degree
|
|
Complex Modulus (G*) (for the 10 measurements)
|
1.896 kPa
|
|
Test Temperature (Specimen 1)
|
64.0 C
|
|
Dynamic Shear, G*/sin(δ)
|
1.93 kPa
|
DIME Test ID: 2026-06-04-150-2
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/16/2026
Date Tested: 07/16/2026
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: RTFO
Test Result Compliance: complies
Additional Comments When Verified:
|
Phase
|
RTFO residue
|
|
Test Gap
|
1 mm
|
|
Test Frequency
|
10.0 rad/s
|
|
Strain Amplitude
|
10.05 %
|
|
Stress Amplitude
|
0.524 kPa
|
|
Phase Angle (δ) (for the 10 cycles)
|
76.5 degree
|
|
Complex Modulus (G*) (for the 10 measurements)
|
5.215 kPa
|
|
Test Temperature (Specimen 1)
|
64.0 C
|
|
Dynamic Shear, G*/sin(δ)
|
5.36 kPa
|
DIME Test ID: 2026-06-04-150-3
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/16/2026
Date Tested: 07/16/2026
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: PAV
Test Result Compliance: complies
Additional Comments When Verified:
|
Phase
|
PAV residue
|
|
Test Plate Diameter
|
8 mm
|
|
Test Gap
|
2 mm
|
|
Test Frequency
|
10.0 rad/s
|
|
Strain Amplitude
|
1.01 %
|
|
Stress Amplitude
|
51.832 kPa
|
|
Phase Angle (δ) (for the 10 cycles)
|
44.5 degree
|
|
Complex Modulus (G*) (for the 10 measurements)
|
5157.210 kPa
|
|
Test Temperature (Specimen 1)
|
22.0 C
|
|
(G*) x sin(δ)=
|
3615 kPa
|
DIME Test ID: 2026-06-04-150-4
Test Method: AASHTO T313-2025: Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 07/16/2026
Date Tested: 07/16/2026
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: BBR
Test Result Compliance: complies
Additional Comments When Verified:
|
Maximum test bath temperature at 240 S
|
0.0 C
|
|
Minimum test bath temperature at 240 S
|
0.0 C
|
|
Estimated Stiffness Modulus 8.0 s
|
0.000 MPa
|
|
Estimated m-value 8.0 s
|
0.000
|
|
Estimated Stiffness Modulus 15.0 s
|
0.000 MPa
|
|
Estimated m-value 15.0 s
|
0.000
|
|
Estimated Stiffness Modulus 30.0 s
|
0.000 MPa
|
|
Estimated m-value 30.0 s
|
0.000
|
|
Estimated Stiffness Modulus 60.0 s
|
263.165 MPa
|
|
Estimated m-value 60.0 s
|
0.329
|
|
Estimated Stiffness Modulus 120.0 s
|
0.000 MPa
|
|
Estimated m-value 120.0 s
|
0.000
|
|
Estimated Stiffness Modulus 240.0 s
|
0.000 MPa
|
|
Estimated m-value 240.0 s
|
0.000
|
DIME Test ID: 2026-06-04-150-5
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Verified Date: 07/16/2026
Date Tested: 07/16/2026
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: VISCOSITY @ 135C
Test Result Compliance: complies
Additional Comments When Verified:
|
Is viscosity reading in cP/Pa-s?
|
Pa-s
|
|
Time of test
|
00:00 HH:MM
|
|
Test Temperature
|
135 C
|
|
Speed
|
100 rpm
|
|
Spindle size
|
.463 in
|
|
Torque
|
62.7 %
|
|
Viscosity reading #1 (A)
|
0.309 Pa-s
|
|
Viscosity reading #2 (B)
|
0.315 Pa-s
|
|
Viscosity reading #3 (C)
|
0.318 Pa-s
|
|
Average viscosity
|
0.314 Pa-s
|
DIME Test ID: 2026-06-04-150-6
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 07/16/2026
Date Tested: 07/16/2026
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: MASS CHANGE
Test Result Compliance: complies
Additional Comments When Verified:
|
Is mass change based on one or two containers?
|
Two
|
|
Is mass change correction factor needed?
|
Yes
|
|
Any material loss from containers during heating process/testing?
|
no data
|
|
Mass of container #1 before test (m1i)
|
206.566 grams
|
|
Mass of container #2 before test (m2i)
|
207.008 grams
|
|
Mass of container #1 after test (m1f)
|
206.409 grams
|
|
Mass of container #2 after test (m2f)
|
206.852 grams
|
|
Average mass change
|
-0.44 percent
|
|
Mass of empty container #1
|
171.465 grams
|
|
Mass of empty container #2
|
171.922 grams
|
|
Mass correction factor
|
0.006
|
DIME Test ID: 2026-06-04-150-7
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Verified Date: 07/16/2026
Date Tested: 07/16/2026
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: DUCTILITY
Test Result Compliance: complies
Additional Comments When Verified:
|
Is a normal test obtainable?
|
Yes
|
|
Number of replicates tested
|
One
|
|
Ductility of test #1 (D1)
|
131 cm
|
|
Ductility of sample
|