Sample Record for 2026-06-25-70
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1001194 DEA: 051H4404 EFIS: 0516000074
QA Service Level: 1
DIST-CO-RTE-PM: 05-SB,SLO-1-50.3/50.6,0.0/0.3
Work Description: SANTA MARIA RIVER BRIDGE (REPLACE).
Location Description: SANTA BARBARA AND SAN LUIS OBISPO COUNTIES IN AND NEAR GUADALUPE AT SANTA MARIA RIVER BRIDGE
Contractor Name: M.C.M. CONSTRUCTION, INC.
Contractor Address: 6413 32nd Street, North Highlands, Ca 95660
Resident Engineer: Jacob Cooper Structure Rep.: Sal Heredia
Sample Information
DIME Sample ID: 2026-06-25-70
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (213) 505-4213
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 06/25/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/30/2026
The quantity of what the sample constitutes: 5
A brief description of the sample: .6in Prestressing Strand
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire
Material Information
Comments:
Reel/Coil/Pack Number(s): S381240-5, S381241-6, S381246-4, S381255-3, S381258-4
Number of Coils:
Group Number:
Strand Diameter:
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0513226, S0253273, S0513426, S0253271, S0253779
Mfg. Lot Number(s): NA
Manufacturer(s): Sumiden Wire
Test Results
Test
DIME Test ID: 2026-06-25-70-1
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 07/22/2026
Date Tested: 07/20/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
5
|
| Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | | S0513226 | S381240-5 | 0.214 | 60600 | 57280 | 29.0 | 4.6 | WSP | | S0253273 | S381241-6 | 0.214 | 60780 | 57340 | 28.5 | 5.0 | WSP | | S0513426 | S381246-4 | 0.216 | 62250 | 57840 | 29.45 | 5.4 | WSP | | S0253271 | S381255-3 | 0.218 | 61030 | 57770 | 29.75 | 4.9 | WSP | | S0253779 | S381258-4 | 0.216 | 61760 | 58270 | 29.4 | 4.4 | WSP |
| |
|
UTM
|
NA
|
|
Temperature
|
0 f
|
|
Extensometers
|
NA
|