Print Report | Back to Sample Detail

Sample Record for 2026-06-29-8

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001117 DEA: 033G4304 EFIS: 0324000127 QA Service Level: 1
DIST-CO-RTE-PM: 03-ED-89-0.0/8.5
Work Description: COLD PLANE AC PVMT AND HMA (TYPE A) OVERLAY.
Location Description: EL DORADO COUNTY NEAR MEYERS FROM ALPINE COUNTY LINE TO POMO STREET
Contractor Name: ALL-AMERICAN CONSTRUCTION, INC.
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-06-29-8
TL Number from the TL Form:
Sample Submitted By Organization: Blackburn Consulting
Sample Organization Contact: (916) 375-8706
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/29/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/29/2026
The quantity of what the sample constitutes: 2 boxes 400 tons out
A brief description of the sample: 1/2 HMA-A-SP 12%RAP
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tahoe Asphalt

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number: 1
Sublot number: 9
HMA Mix Number: 2001
Binder content (%): 5.2
Virgin binder PG: PG 64-28
Design binder PG: PG 64-28
Binder Supplier: VSS Emultech
RAP content (%): 12
WMA Additives: No
Antistrip type:

Test Results

Test

DIME Test ID: 2026-06-29-8-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 06/30/2026
Date Tested: 06/30/2026
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7402.5 grams
Mass of oven-dry sample in air for Sample 1 1622.4 grams
Mass of container filled with the sample and water for Sample 1 8391.6 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.562
Theoretical maximum density at 25°C (77°F) 2554.6 kg/m^3

Test

DIME Test ID: 2026-06-29-8-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/30/2026
Date Tested: 06/30/2026
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: R1 OBC 5.2
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 1683.6 g
Corrected Asphalt Binder Content 5.18 %
Mass Loss 100.8 g
Correction Factor (Percent by mass of HMA Specimen) 0.81 %
Moisture Content no data0 %
Temperature Compensation Factor 0.02 %
Test Temperature 538 C