Sample Record for 2026-05-18-73

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215734 DEA: 024H0104 EFIS: 0218000068 QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-70-78.3/90.3
Work Description: REPLACE AC SURFACING, PLACE HMA AND THERMOPLASTIC TRAFFIC STRIPING.
Location Description: PLUMAS COUNTY NEAR PORTOLA FROM 0.4 MILE WEST OF BIG GRIZZLY CREEK BRIDGE TO 0.8 MILE WEST OF SUMMIT SCHOOL DRIVE
Contractor Name: HAT CREEK CONSTRUCTION & MATERIALS, INC.
Contractor Address: 243339 Hwy 89, N Burney, CA 96013
Resident Engineer: Mike Zdenek Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-05-18-73
TL Number from the TL Form: 036628
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Production Start-Up
Type of Material: Reclaimed Asphalt Pavement
Sample Taken Date: 05/18/2026
Date that the sample was received by the laboratory/organization performing the testing: 05/22/2026
The quantity of what the sample constitutes: Production Start-Up Evaluation
A brief description of the sample: 2 bags of Fine RAP
From where was the sample collected: Manufacturer
Laboratory sample identification: D80210B
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Hat Creek Construction & Materials — Ward Lake Plant (Litchfield, CA)

Material Information

RAP Source: Ward Lake Plant
Aggregate Size: 3/8-inch
Aggregate Source:
RAP Stockpile:
Stockpile Size (tons):
Reclaimed Asphalt Pavement Mix Number:

Test Results

Test

DIME Test ID: 2026-05-18-73-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/26/2026
Date Tested: 06/02/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pbr(uncorrected)=6.46%, Pbr≈4.98%
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3019.4 g
Mass of the specimen and specimen basket assembly prior to ignition 4624.3 g
Mass of HMA Sample prior to ignition 1604.9 g
Corrected Asphalt Binder Content 6.46 %
Mass Loss 106.7 g
Mass of aggregate remaining after ignition 1498.2 g
Correction Factor (Percent by mass of HMA Specimen) no data0 %
Moisture Content no data0 %
Temperature Compensation Factor 0.19 %
Test Temperature 538 C

Test

DIME Test ID: 2026-05-18-73-2
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 06/26/2026
Date Tested: 06/03/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Is an aggregate correction factor used? Yes
Aggregate correction factor for the 2 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1 1/2 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1 in. sieve (% passing) no data0 %
Aggregate correction factor for the 3/4 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1/2 in. sieve (% passing) no data0 %
Aggregate correction factor for the 3/8 in. sieve (% passing) -0.2 %
Aggregate correction factor for the #4 sieve (% passing) 1.3 %
Aggregate correction factor for the #8 sieve (% passing) 2.8 %
Aggregate correction factor for the #16 sieve (% passing) 3.2 %
Aggregate correction factor for the #30 sieve (% passing) 2.3 %
Aggregate correction factor for the #50 sieve (% passing) 1.3 %
Aggregate correction factor for the #100 sieve (% passing) 0.8 %
Aggregate correction factor for the #200 sieve (% passing) 0.4 %
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 100 %
Cumulative percent passing the 3/8 in. sieve 96 %
Cumulative percent passing the #4 sieve 65 %
Cumulative percent passing the #8 sieve 47 %
Cumulative percent passing the #16 sieve 36 %
Cumulative percent passing the #30 sieve 28 %
Cumulative percent passing the #50 sieve 21 %
Cumulative percent passing the #100 sieve 16 %
Cumulative percent passing the #200 sieve 11.4 %

Test

DIME Test ID: 2026-05-18-73-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 06/26/2026
Date Tested: 05/26/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmmr=2.500, Gser≈2.699
Test Result Compliance: complies
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7330.6 grams
Mass of oven-dry sample in air for Sample 1 1504.5 grams
Mass of container filled with the sample and water for Sample 1 8233.3 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.5
Theoretical maximum density at 25°C (77°F) 2492.8 kg/m^3