Print Report | Back to Sample Detail

Sample Record for 2018-03-19-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2018-03-19-2
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Proficiency
Type of Material: Cementitious
Sample Taken Date: 03/19/2018
Date that the sample was received by the laboratory/organization performing the testing: 03/19/2018
The quantity of what the sample constitutes: 1 Bucket
A brief description of the sample: Blended cement
From where was the sample collected: Source
Laboratory sample identification: CM188081
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CCRL

Material Information

Brand: CCRL
Mill: CCRL
Type of Cementitious Material: Blended Cement

Test Results

Test 1 of 10

DIME Test ID: 2018-03-19-2-2
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Verified Date: 03/22/2019
Date Tested: 03/22/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 3 Day Break
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311? no
Compressive strength of 1st specimen (psi) 3432 psi
Compressive strength of 2nd specimen (psi) 3499 psi
Compressive strength of 3rd specimen (psi) 3558 psi
Average Compressive strength (to nearest 10 psi) 3500 psi

Test 2 of 10

DIME Test ID: 2018-03-19-2-3
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Verified Date: 03/22/2019
Date Tested: 03/26/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 7 Day Break
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311? no
Compressive strength of 1st specimen (psi) 4581 psi
Compressive strength of 2nd specimen (psi) 4633 psi
Compressive strength of 3rd specimen (psi) 4477 psi
Average Compressive strength (to nearest 10 psi) 4560 psi

Test 3 of 10

DIME Test ID: 2018-03-19-2-4
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Verified Date: 03/22/2019
Date Tested: 04/16/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 28 Day Break
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311? no
Compressive strength of 1st specimen (psi) 5590 psi
Compressive strength of 2nd specimen (psi) 6152 psi
Compressive strength of 3rd specimen (psi) 5454 psi
Average Compressive strength (to nearest 10 psi) 5730 psi

Test 4 of 10

DIME Test ID: 2018-03-19-2-5
Test Method: ASTM C151-15: Standard Test Method for Autoclave Expansion of Hydraulic Cement
Verified Date: 03/22/2019
Date Tested: 04/05/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Initial length of specimen 0.2271
Final length of specimen 0.2315
Change in length of specimen(In percent) 1.94 %
Gauge Length no data

Test 5 of 10

DIME Test ID: 2018-03-19-2-6
Test Method: ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement Mortar
Verified Date: 03/22/2019
Date Tested: 04/17/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Specific gravity 3.039
Water Content 232
The amount of flow (In percent) 87 %
The amount of water used (In percent) 66.29 %
Net Weight of Sample 816.8 grams
Air Content 10 %

Test 6 of 10

DIME Test ID: 2018-03-19-2-7
Test Method: ASTM C188-15: Standard Test Method for Density of Hydraulic Cement
Verified Date: 03/22/2019
Date Tested: 04/10/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Density of hydraulic cement 3.039 g/cm^3

Test 7 of 10

DIME Test ID: 2018-03-19-2-8
Test Method: ASTM C187-16: Standard Test Method for Amount of Water Required for Normal Consistency of Hydraulic Cement Paste (Water Normal Consistency)
Verified Date: 03/22/2019
Date Tested: 04/17/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Mass of Water 174 g
Mass of Dry Cement 650 g
Water required for normal consistency 27.0 %

Test 8 of 10

DIME Test ID: 2018-03-19-2-9
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Verified Date: 03/22/2019
Date Tested: 04/05/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Type of Water Used Type III grade reagent water
Time in minutes of last penetration greater than 25mm (E) 117 min
Time in minutes of first penetration less than 25mm (H) 116 min
Penetration reading at time E 26 mm
Penetration reading at time H 25 mm
Initial time of setting 116 min
Final time of setting 225 min
Method Used Test Method A

Test 9 of 10

DIME Test ID: 2018-03-19-2-10
Test Method: ASTM C204-11: Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatus
Verified Date: 03/22/2019
Date Tested: 04/11/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method Used Test Method A
Test Time 132 seconds
Fineness 4792 cm^2/g

Test 10 of 10

DIME Test ID: 2018-03-19-2-11
Test Method: ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve
Verified Date: 03/22/2019
Date Tested: 03/22/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Corrected residue, % (Rc) 3.1 %
Fineness of the cement as the corrected percentage passing the 45 micrometers sieve (No. 325) 96.9 %