Print Report | Back to Sample Detail

Sample Record for 2026-06-16-78

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001404 DEA: 120S3804 EFIS: 1220000058 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-5-10.0/21.3
Work Description: SLAB REPLACEMENT (RSC), RHMA-PAVING, SIGNAL AND LIGHTING MODIFICATION.
Location Description: ORANGE COUNTY FROM EL HORNO STREET UNDERCROSSING IN SAN JUAN CAPISTRANO TO ROUTE 405/5 SEPARATION IN IRVINE
Contractor Name: Beador Construction
Contractor Address: 2900 Bristol Street, Suite D 204, Costa Mesa, CA 92626
Resident Engineer: Artin Merati Structure Rep.: Michael Yee

Sample Information

DIME Sample ID: 2026-06-16-78
TL Number from the TL Form:
Sample Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Sample Organization Contact: 9492798846
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 06/16/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/16/2026
The quantity of what the sample constitutes: 3
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 26-0134
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Short Load Concrete

Material Information

The concrete mix design number: CTS-65-EHI
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: Unknown
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Discharge from concrete truck into wheelbarrow.
Where the material sample would have been placed if not sampled: 5/73 To Avery, Lanes HOV, #1 & 2
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2026-06-16-78-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 06/26/2026
Date Tested: 06/26/2026
Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Organization Address: 19601 Beach Boulevard,
Organization City: Huntington Beach
Organization State: CA
Organization Zipcode: 92648
Organization Email: frank.mai@dot.ca.gov
Organization Phone: (949) 279-8846
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 6.02 in
Average diameter of cylinder 2 6.01 in
Average diameter of cylinder 3 6.01 in
Cross sectional area of cylinder 1 28.46 in^2
Cross sectional area of cylinder 2 28.37 in^2
Cross sectional area of cylinder 3 28.37 in^2
Compressive strength (to nearest 10 psi) 6920 psi
Maximum load on cylinder 1 196500 lb
Maximum load on cylinder 2 195600 lb
Maximum load on cylinder 3 197760 lb
Compressive strength of cylinder 1 6904.4 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 6894.6 psi
Compressive strength of cylinder 3 6970.7 psi
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 10 days
Age of specimen in hours no data0 hours