Sample Record for 2026-06-24-18
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1001197 DEA: 07319604 EFIS: 0716000025
QA Service Level: 1
DIST-CO-RTE-PM: 07-VEN-1,101-21.3/21.9,R34.9/R36.1
Work Description: REMOVE AND CONSTRUCT BRIDGE.
Location Description: VENTURA COUNTY ON ROUTE 1 FROM 1.8 MILES NORTH OF ROUTE 1/33 SEPARATION TO 2.0 MILES SOUTH OF A LEASE CANYON ROAD AND ON ROUTE 101 FROM 0.4 MILE NORTH OF DULAH ROAD UNDERCROSSING TO SAN MIGUELITO ROAD UNDERCROSSING
Contractor Name: BEADOR CONSTRUCTION COMPANY, INC.
Contractor Address: 2900 BRISTOL STREET, SUITE D204, COSTA MESA, CA 92626
Resident Engineer: Ranjit Singh Structure Rep.: Aziz Maghsoudloo
Sample Information
DIME Sample ID: 2026-06-24-18
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Vallejo Field Laboratory
Sample Organization Contact: 9166394315
Type of Sample: Quality Assurance
Type of Material: Precast Concrete
Sample Taken Date: 06/24/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/25/2026
The quantity of what the sample constitutes: 10 CY
A brief description of the sample: set of three 4x8 cylinders
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Pinnacle Prestress, Inc.
Material Information
The concrete mix design number: SSC-ASH25-SF07-9.22-FC6K REV01
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 345
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete Sample from Wheelbarrow
Where the material sample would have been placed if not sampled: Voided Slab - Mark VS-03
From Lot No.:
Bag Lot No.:
Test Results
Test
DIME Test ID: 2026-06-24-18-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 07/22/2026
Date Tested: 07/22/2026
Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Organization Address: 1824 Norris Road,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: kulwinder.rai@dot.ca.gov
Organization Phone: (661) 549-8281
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Apparent mass of submerged cylinder 1
|
5.16 lb
|
|
Average diameter of cylinder 1
|
3.99 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.5 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
6760 psi
|
|
Maximum load on cylinder 1
|
89030 lb
|
|
Maximum load on cylinder 2
|
88320 lb
|
|
Maximum load on cylinder 3
|
77120 lb
|
|
Compressive strength of cylinder 1
|
7120.0 psi
|
|
Type of fracture pattern of cylinder 1
|
5
|
|
Compressive strength of cylinder 2
|
7030.0 psi
|
|
Compressive strength of cylinder 3
|
6140 psi
|
|
Type of fracture pattern of cylinder 2
|
4
|
|
Type of fracture pattern of cylinder 3
|
4
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
28 days
|
|
Age of specimen in hours
|
no data0 hours
|
|
Serial number of delivery ticket, if available
|
no data
|