Print Report | Back to Sample Detail

Sample Record for 2026-06-10-75

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993595 DEA: 042Q5504 EFIS: 0419000024 QA Service Level: 1
DIST-CO-RTE-PM: 04-SOL-12-7.9/14.1
Work Description: RHMA OVERLAY, REPLACE CULVERTS, BRIDGE RAILS, AND MEDIAN BARRIERS.
Location Description: SOLANO COUNTY NEAR SUISUN CITY FROM 0.2 MILE EAST OF LAWLER RANCH PARKWAY TO 0.5 MILE EAST OF SHILOH ROAD
Contractor Name: BAY CITIES PAVING & GRADING, INC.
Contractor Address: 1450 Civic Court B#400, Concord, CA 94520
Resident Engineer: Asadullah Sarwary Structure Rep.: Kambiz Kouchesfahani

Sample Information

DIME Sample ID: 2026-06-10-75
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Hayward Field Laboratory
Sample Organization Contact: (510) 723-0168
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/10/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/10/2026
The quantity of what the sample constitutes: 24 boxes
A brief description of the sample: 1/2" RWMA
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Teichert Woodland Batch Plant

Material Information

HMA Type: RHMA-G
HMA Grading: 1/2 inch
Lot number: 1
Sublot number: 12
HMA Mix Number:
Binder content (%): 0.0
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test

DIME Test ID: 2026-06-10-75-35
Test Method: AASHTO T209-25: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 06/24/2026
Date Tested: 06/12/2026
Submitted By Organization: CT D04 - Hayward Field Laboratory
Organization Address: 21339 Cabot Boulevard,
Organization City: Hayward
Organization State: CA
Organization Zipcode: 94545
Organization Email: pamela.brown@dot.ca.gov
Organization Phone: (510) 385-8258
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Specific Gravity for Sample 1 2.397
Theoretical maximum density at 25°C (77°F) 2390 kg/m^3

Test

DIME Test ID: 2026-06-10-75-36
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 06/24/2026
Date Tested: 06/12/2026
Submitted By Organization: CT D04 - Hayward Field Laboratory
Organization Address: 21339 Cabot Boulevard,
Organization City: Hayward
Organization State: CA
Organization Zipcode: 94545
Organization Email: pamela.brown@dot.ca.gov
Organization Phone: (510) 385-8258
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity 2.226
Bulk Specific Gravity 2 2.246
Bulk Specific Gravity 3 2.252
Average Bulk Specific Gravity 2.241

Test

DIME Test ID: 2026-06-10-75-37
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/24/2026
Date Tested: 06/12/2026
Submitted By Organization: CT D04 - Hayward Field Laboratory
Organization Address: 21339 Cabot Boulevard,
Organization City: Hayward
Organization State: CA
Organization Zipcode: 94545
Organization Email: pamela.brown@dot.ca.gov
Organization Phone: (510) 385-8258
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Corrected Asphalt Binder Content 8.04 %
Mass of HMA Sample prior to ignition 1582.6 g
Mass Loss 142.3 g
Correction Factor (Percent by mass of HMA Specimen) 0.76 %
Moisture Content no data0 %
Temperature Compensation Factor 0.19 %
Test Temperature 565 C