Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000710 DEA: 100P9244 EFIS: 1023000226
QA Service Level: 1
DIST-CO-RTE-PM: 10-MPA-140-42.0/42.7
Work Description: Fergusen Slide Rock Avalanche Shed
Location Description: Mariposa County, along Route 140 in the Merced River canyon, about 8 miles east of Briceburg and 7.6 miles west of El Portal.
Contractor Name: Myers and Sons Construction, LLC/Ralph L. Wadsworth
Contractor Address: 2554 Millcreek Drive, Sacramento, CA 95833
Resident Engineer: Jonathan Ngai Structure Rep.: Natasha Collins
DIME Sample ID: 2026-06-18-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 06/18/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/18/2026
The quantity of what the sample constitutes: 4 samples from each pack
A brief description of the sample: 4 EA 5ft long epoxy coated strand samples from each spool per SS Section 50-1.01C(5)
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden
Comments:
Reel/Coil/Pack Number(s): T350418-4, T350418-6
Number of Coils: 2
Group Number:
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 882
Heat Number(s): T0253276
Mfg. Lot Number(s): W76102924-1
Manufacturer(s): Sumiden Wire Products Corporation
DIME Test ID: 2026-06-18-2-1
Test Method: ASTM A882-20: Standard Specification for Filled Epoxy-Coated Seven-Wire Prestressing Steel Strand (Withdrawn 2019) (Coating Adhesion)
Verified Date: 06/23/2026
Date Tested: 06/23/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test: T350418-4
Test Result Compliance: complies
Additional Comments When Verified:
|
Coating Adhesion Pass/Fail
|
Pass
|
DIME Test ID: 2026-06-18-2-2
Test Method: ASTM A882-20: Standard Specification for Filled Epoxy-Coated Seven-Wire Prestressing Steel Strand (Withdrawn 2019) (Coating Adhesion)
Verified Date: 06/23/2026
Date Tested: 06/23/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test: T350418-6
Test Result Compliance: complies
Additional Comments When Verified:
|
Coating Adhesion Pass/Fail
|
Pass
|