Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000481 DEA: 081C07U4 EFIS: 0824000168
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-74-27.5/34.3
Work Description: RUBBERIZED HMA, FIBER OPTIC CABLE SYSTEMS, AND COLD PLANE AC PAVEMENT.
Location Description: RIVERSIDE COUNTY AT AND NEAR ROMOLAND AND HOMELAND FROM BONNIE DRIVE TO WINCHESTER ROAD
Contractor Name: GRIFFITH COMPANY
Contractor Address: 12200 Bloomfield Avenue, Santa Fe Springs, CA 90670
Resident Engineer: Omar Sanchez Structure Rep.: Unknown
DIME Sample ID: 2026-06-11-28
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Binder
Sample Taken Date: 06/11/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/16/2026
The quantity of what the sample constitutes: 1can
A brief description of the sample: Asphalt Binder Sample
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Mariett(CCA) Lake Elsinore
Performance Grade: PG 64-16
Modified:
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: Valero Wilmington Refinery - Wilmington CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:
HMA Type:
HMA Supplier Mix ID Number:
DIME Test ID: 2026-06-11-28-3
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/01/2026
Date Tested: 06/17/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Phase
|
Original binder
|
|
Phase Angle (δ) (for the 10 cycles)
|
85.5 degree
|
|
Dynamic Shear, G*/sin(δ)
|
1.38 kPa
|
DIME Test ID: 2026-06-11-28-4
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/01/2026
Date Tested: 06/17/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Phase
|
RTFO residue
|
|
Phase Angle (δ) (for the 10 cycles)
|
80.4 degree
|
|
Dynamic Shear, G*/sin(δ)
|
4.05 kPa
|
DIME Test ID: 2026-06-11-28-6
Test Method: AASHTO T44-18: Standard Method of Test for Solubility of Bituminous Materials
Verified Date: 07/01/2026
Date Tested: 06/17/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Was test performed on residue from distillation or evaporation?
|
NA
|
|
Soluble, percent
|
99.90 %
|
|
Insoluble, percent
|
0.10 %
|
DIME Test ID: 2026-06-11-28-5
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Verified Date: 07/01/2026
Date Tested: 06/17/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Is viscosity reading in cP/Pa-s?
|
Pa-s
|
|
Time of test
|
8:26 HH:MM
|
|
Test Temperature
|
135 C
|
|
Speed
|
100 rpm
|
|
Spindle size
|
21 in
|
|
Torque
|
75.6 %
|
|
Viscosity reading #1 (A)
|
0.377 Pa-s
|
|
Viscosity reading #2 (B)
|
0.378 Pa-s
|
|
Viscosity reading #3 (C)
|
0.38 Pa-s
|
|
Average viscosity
|
0.378 Pa-s
|
DIME Test ID: 2026-06-11-28-1
Test Method: AASHTO T228-22: Standard Method of Test for Specific Gravity of Semi-Solid Asphalt Materials (Specific Gravity)
Verified Date: 07/01/2026
Date Tested: 06/17/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
DIME Test ID: 2026-06-11-28-2
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 07/01/2026
Date Tested: 06/17/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Is mass change based on one or two containers?
|
Two
|
|
Is mass change correction factor needed?
|
Yes
|
|
Any material loss from containers during heating process/testing?
|
No
|
|
Mass of container #1 before test (m1i)
|
206.051 grams
|
|
Mass of container #2 before test (m2i)
|
202.602 grams
|
|
Mass of container #1 after test (m1f)
|
205.891 grams
|
|
Mass of container #2 after test (m2f)
|
202.438 grams
|
|
Average mass change
|
-0.455 percent
|
|
Mass of empty container #1
|
170.915 grams
|
|
Mass of empty container #2
|
167.461 grams
|
|
Mass correction factor
|
0.006
|
DIME Test ID: 2026-06-11-28-7
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Verified Date: 07/01/2026
Date Tested: 06/18/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Is a normal test obtainable?
|
Yes
|
|
Number of replicates tested
|
One
|
|
Ductility of test #1 (D1)
|
122 cm
|
|
Ductility of sample
|
122 cm
|
DIME Test ID: 2026-06-11-28-8
Test Method: AASHTO T313-2025: Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 07/01/2026
Date Tested: 06/30/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Maximum test bath temperature at 240 S
|
0.0 C
|
|
Minimum test bath temperature at 240 S
|
0.0 C
|
|
Estimated Stiffness Modulus 8.0 s
|
0.000 MPa
|
|
Estimated m-value 8.0 s
|
0.000
|
|
Estimated Stiffness Modulus 15.0 s
|
0.000 MPa
|
|
Estimated m-value 15.0 s
|
0.000
|
|
Estimated Stiffness Modulus 30.0 s
|
0.000 MPa
|
|
Estimated m-value 30.0 s
|
0.000
|
|
Estimated Stiffness Modulus 60.0 s
|
78.746 MPa
|
|
Estimated m-value 60.0 s
|
0.360
|
|
Estimated Stiffness Modulus 120.0 s
|
0.000 MPa
|
|
Estimated m-value 120.0 s
|
0.000
|
|
Estimated Stiffness Modulus 240.0 s
|
0.000 MPa
|
|
Estimated m-value 240.0 s
|
0.000
|
DIME Test ID: 2026-06-11-28-9
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/03/2026
Date Tested: 06/30/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Phase
|
PAV residue
|
|
Test Plate Diameter
|
8 mm
|
|
Phase Angle (δ) (for the 10 cycles)
|
57.1 degree
|
|
(G*) x sin(δ)=
|