Sample Record for 2026-06-16-23
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 995026 DEA: 040Q1004 EFIS: 0418000044
QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-580-20.7/30.8
Work Description: REHAB ALA 580
Location Description: ALAMEDA COUNTY IN PLEASANTON AND CASTRO VALLEY FROM ROUTE 680/580 SEPARATION TO ROUTE 580/238 SEPARATION
Contractor Name: FBD VANGUARD CONSTRUCTION, INC.
Contractor Address: 550 Greenville Road, Livermore, CA 94550
Resident Engineer: Paramjit Pandher Structure Rep.: John Parecadan
Sample Information
DIME Sample ID: 2026-06-16-23
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Vallejo Field Laboratory
Sample Organization Contact: 9166394315
Type of Sample: Stock
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 06/16/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/29/2026
The quantity of what the sample constitutes: 100
A brief description of the sample: 3/4"x 8" F1554 all thread rods
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: UIS
Material Information
Rocap Number(s): N/A
Heat Number(s): 1201048948
Nut Mfg. Lot Number(s): xxx
Washer Mfg. Lot Number(s): xxx
Bolt Specification: F1554
Bolt Length(s): 8.0"
Nut Specification: xxx
Washer Specification: xxx
Finish: HDG
Diameter/Size: 3/4"
Bolt Mfg. Lot Number: 1201048948
Rocap Test Requirement(s): xxx
Lubricant Requirements(s): xxx
Washer Inner Diameter(s): xxx
Test Results
Test
DIME Test ID: 2026-06-16-23-1
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/09/2026
Date Tested: 07/08/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
120104894860
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
7.3 mils
|
Test
DIME Test ID: 2026-06-16-23-2
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/09/2026
Date Tested: 07/08/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
120104894860
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
6.7 mils
|
Test
DIME Test ID: 2026-06-16-23-3
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 07/09/2026
Date Tested: 07/08/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Bolt Samples
|
1
|
| Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | | 1A | 120104894860 | 0.75 | 24285 | 0 | 0 | Tensile | WSP |
| |
|
UTM
|
NA
|
|
Temperature
|
0 f
|
Test
DIME Test ID: 2026-06-16-23-4
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 07/09/2026
Date Tested: 07/09/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1201048948
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
.75 in
|
|
Bolt Length
|
8 in
|
|
Pitch Diameter
|
0.6795 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test
DIME Test ID: 2026-06-16-23-5
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 07/09/2026
Date Tested: 07/09/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1201048948
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
.75 in
|
|
Bolt Length
|
8 in
|
|
Pitch Diameter
|
0.6780 in
|
|
Pitch Diameter 2nd
|
no data in
|