Print Report | Back to Sample Detail

Sample Record for 2026-05-19-77

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1002012 DEA: 034J4304 EFIS: 0323000146 QA Service Level: 1
DIST-CO-RTE-PM: 03-UNKNOWN--
Work Description: Building Construction
Location Description: KYBURZ MAINTENANCE STATION AT 13561 HIGHWAY 50
Contractor Name: Dawood Kavosh
Contractor Address: 2002 Elijah St, Fairfield2002 Elijah St, Fairfield, CA 94533, CA 94533
Resident Engineer: Spencer Adams Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-05-19-77
TL Number from the TL Form: 201054
Sample Submitted By Organization: CT SC - 3665 - Shingle Springs
Sample Organization Contact: (530) 821-8266
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 05/19/2026
Date that the sample was received by the laboratory/organization performing the testing: 05/21/2026
The quantity of what the sample constitutes: 9 Cylinders
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: Kyburz Maintenance Station Hydronics Slab (Interior)
The fabricator/manufacturer/facility name: Sierra Tahoe Ready Mix

Material Information

The concrete mix design number: D673A
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: Unknown
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Chute
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test

DIME Test ID: 2026-05-19-77-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 06/16/2026
Date Tested: 05/26/2026
Submitted By Organization: CT SC - 3665 - Shingle Springs
Organization Address: 3976 Durock Road, Suite 102,
Organization City: Shingle Springs
Organization State: CA
Organization Zipcode: 95686
Organization Email: brandon.miller@dot.ca.gov
Organization Phone: (530) 821-8266
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 4.01 in
Average diameter of cylinder 2 4.01 in
Average diameter of cylinder 3 4.02 in
Cross sectional area of cylinder 1 12.63 in^2
Cross sectional area of cylinder 2 12.63 in^2
Cross sectional area of cylinder 3 12.69 in^2
Compressive strength (to nearest 10 psi) 1930 psi
Maximum load on cylinder 1 25850 lb
Maximum load on cylinder 2 22600 lb
Maximum load on cylinder 3 24600 lb
Compressive strength of cylinder 1 2050.0 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 1790.0 psi
Compressive strength of cylinder 3 1940 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 7 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data

Test

DIME Test ID: 2026-05-19-77-2
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 06/16/2026
Date Tested: 06/02/2026
Submitted By Organization: CT SC - 3665 - Shingle Springs
Organization Address: 3976 Durock Road, Suite 102,
Organization City: Shingle Springs
Organization State: CA
Organization Zipcode: 95686
Organization Email: brandon.miller@dot.ca.gov
Organization Phone: (530) 821-8266
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 4.02 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.69 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 2890 psi
Maximum load on cylinder 1 37160 lb
Maximum load on cylinder 2 37620 lb
Maximum load on cylinder 3 34580 lb
Compressive strength of cylinder 1 2930.0 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 2990.0 psi
Compressive strength of cylinder 3 2750 psi
Type of fracture pattern of cylinder 2 1
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 14 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data

Test

DIME Test ID: 2026-05-19-77-3
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 06/16/2026
Date Tested: 06/16/2026
Submitted By Organization: CT SC - 3665 - Shingle Springs
Organization Address: 3976 Durock Road, Suite 102,
Organization City: Shingle Springs
Organization State: CA
Organization Zipcode: 95686
Organization Email: brandon.miller@dot.ca.gov
Organization Phone: (530) 821-8266
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 4120 psi
Maximum load on cylinder 1 54160 lb
Maximum load on cylinder 2 50120 lb
Maximum load on cylinder 3 51100 lb
Compressive strength of cylinder 1 4310.0 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 3990.0 psi
Compressive strength of cylinder 3 4070 psi
Type of fracture pattern of cylinder 2 5
Type of fracture pattern of cylinder 3 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data