Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1002310 DEA: 010P6404 EFIS: 0125000053
QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-101-R131.7/134.6
Work Description: Boyes Creek Viaduct
Location Description:
Contractor Name: GR Sundberg Inc
Contractor Address: 5211 Boyd Road, Arcata CA, 95521
Resident Engineer: Ryan Dunne Structure Rep.: Unknown
DIME Sample ID: 2026-06-12-2
TL Number from the TL Form:
Sample Submitted By Organization: CT D01 - Boyd Road Field Laboratory
Sample Organization Contact: (707) 496-0974
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/12/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/12/2026
The quantity of what the sample constitutes: 4 boxs
A brief description of the sample: 1/2 RHMA PG 64-16
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Mercer Fraser Boyd Road
DIME Test ID: 2026-06-12-2-3
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/12/2026
Date Tested: 06/12/2026
Submitted By Organization: CT D01 - Boyd Road Field Laboratory
Organization Address: 1050 River Ranch Road,
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3922.4 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5458.4 g
|
|
Corrected Asphalt Binder Content
|
7.73 %
|
|
Mass of HMA Sample prior to ignition
|
1536 g
|
|
Mass Loss
|
135.3 g
|
|
Mass of aggregate remaining after ignition
|
1400.7 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.95 %
|
|
Moisture Content
|
0.13 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|