Print Report | Back to Sample Detail

Sample Record for 2026-05-15-72

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000513 DEA: 020J8504 EFIS: 0219000168 QA Service Level: 1
DIST-CO-RTE-PM: 02-SIS-89-21/R34.622
Work Description: MCCLOUD CAPM - PAVEMENT REHABILITATION
Location Description: IN SISKIYOU COUNTY AT AND NEAR MCCLOUD FROM 0.1 MILE SOUTH OF MUD CREEK BRIDGE TO ROUTE 5
Contractor Name: TULLIS, INC.
Contractor Address: Unknown
Resident Engineer: Austin Henry Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-05-15-72
TL Number from the TL Form: 877622
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/15/2026
Date that the sample was received by the laboratory/organization performing the testing: 05/15/2026
The quantity of what the sample constitutes: Production Start-Up Evaluation
A brief description of the sample: 16 boxes of Lime Treated 3/8-inch Type A HMA (eq. PG 64-16)
From where was the sample collected: Manufacturer
Laboratory sample identification: D80197
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tullis — Northstate Asphalt (Redding, CA)

Material Information

HMA Type: Type A HMA
HMA Grading: 3/8 inch
Lot number: 1
Sublot number: 1
HMA Mix Number: 2607P01
Binder content (%): 5.8
Virgin binder PG: PG 58-22
Design binder PG: PG 64-16
Binder Supplier: Albina (Klamath Falls, OR)
RAP content (%): 25
WMA Additives: No
Antistrip type: Lime

Test Results

Test

DIME Test ID: 2026-05-15-72-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/11/2026
Date Tested: 05/27/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pb=6.11%
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3159.8 g
Mass of the specimen and specimen basket assembly prior to ignition 4764.8 g
Mass of HMA Sample prior to ignition 1605 g
Corrected Asphalt Binder Content 6.11 %
Mass Loss 112.4 g
Mass of aggregate remaining after ignition 1492.6 g
Correction Factor (Percent by mass of HMA Specimen) 0.71 %
Moisture Content no data0 %
Temperature Compensation Factor 0.18 %
Test Temperature 538 C

Test

DIME Test ID: 2026-05-15-72-2
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 06/11/2026
Date Tested: 05/28/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Is an aggregate correction factor used? Yes
Aggregate correction factor for the 2 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1 1/2 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1 in. sieve (% passing) no data0 %
Aggregate correction factor for the 3/4 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1/2 in. sieve (% passing) no data0 %
Aggregate correction factor for the 3/8 in. sieve (% passing) 0.5 %
Aggregate correction factor for the #4 sieve (% passing) 0.2 %
Aggregate correction factor for the #8 sieve (% passing) -0.1 %
Aggregate correction factor for the #16 sieve (% passing) -0.2 %
Aggregate correction factor for the #30 sieve (% passing) -0.4 %
Aggregate correction factor for the #50 sieve (% passing) -0.5 %
Aggregate correction factor for the #100 sieve (% passing) -0.7 %
Aggregate correction factor for the #200 sieve (% passing) -0.9 %
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 100 %
Cumulative percent passing the 3/8 in. sieve 100 %
Cumulative percent passing the #4 sieve 68 %
Cumulative percent passing the #8 sieve 42 %
Cumulative percent passing the #16 sieve 29 %
Cumulative percent passing the #30 sieve 21 %
Cumulative percent passing the #50 sieve 15 %
Cumulative percent passing the #100 sieve 12 %
Cumulative percent passing the #200 sieve 8.8 %

Test

DIME Test ID: 2026-05-15-72-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 06/11/2026
Date Tested: 05/19/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmm=2.471
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7330.6 grams
Mass of oven-dry sample in air for Sample 1 1623.9 grams
Mass of container filled with the sample and water for Sample 1 8297.4 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.471
Theoretical maximum density at 25°C (77°F) 2463.8 kg/m^3

Test

DIME Test ID: 2026-05-15-72-4
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 06/11/2026
Date Tested: 05/19/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmb=2.408
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity 2.41
Bulk Specific Gravity 2 2.409
Bulk Specific Gravity 3 2.405
Average Bulk Specific Gravity 2.408

Test

DIME Test ID: 2026-05-15-72-5
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 06/11/2026
Date Tested: 05/19/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: AASHTO T 269: Pa=2.6%; MS-2: VMA=14.0%, VFA=81.7%, DP=1.8
Test Result Compliance: does not comply
Additional Comments When Verified:
Percent Air Voids 2.5 %
Percent Air Voids 2 2.5 %
Percent Air Voids 3 2.7 %
Average Percent Air Voids 2.6 %

Test

DIME Test ID: 2026-05-15-72-6
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 06/11/2026
Date Tested: 05/27/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: S₁=153psi, S₂=157psi, TSR=102%
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? SI Units
Average Dry Tensile Strength 153 psi
Average Wet Tensile Strength 157 psi
Tensile Strength Ratio 1.03

Test

DIME Test ID: 2026-05-15-72-7
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 06/11/2026
Date Tested: 05/22/2026
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: CT 360: SA=0.3g/cm²; CT 389: Rut=0.1in.@N₁₅₀₀₀, Nf>15000, SIP>15000
Test Result Compliance: complies
Additional Comments When Verified:
Specimen Preparation Method PMLC
Test Temperature 122 F
Air Void Content for specimen A-1 6.9 %
Air Void Content for specimen A-2 7.5 %
Air Void Content for specimen B-1 7.1 %
Air Void Content for specimen B-2 7.3 %
Stripping Inflection Point (Wheel A) >15000
Stripping Inflection Point (Wheel B) >15000
Maximum impression at 5000 passes (left wheel) 2.04 mm
Maximum impression at 5000 passes (right wheel) 2.33 mm
Average impression at 5000 passes (left/right avg) 2.19 mm
Maximum impression at 10000 passes (left wheel) 2.38 mm
Maximum impression at 10000 passes (right wheel) 2.63 mm
Average impression at 10000 passes (left/right avg) 2.5 mm
Maximum impression at 15000 passes (left wheel) 2.62 mm
Maximum impression at 15000 passes (right wheel) 2.85 mm
Average impression at 15000 passes (left/right avg) 2.74 mm
Average impression at 20000 passes (left/right avg) no data
Average impression at 25000 passes (left/right avg) no data