Sample Record for 2026-06-01-76
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1001404 DEA: 120S3804 EFIS: 1220000058
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-5-10.0/21.3
Work Description: SLAB REPLACEMENT (RSC), RHMA-PAVING, SIGNAL AND LIGHTING MODIFICATION.
Location Description: ORANGE COUNTY FROM EL HORNO STREET UNDERCROSSING IN SAN JUAN CAPISTRANO TO ROUTE 405/5 SEPARATION IN IRVINE
Contractor Name: Beador Construction
Contractor Address: 2900 Bristol Street, Suite D 204, Costa Mesa, CA 92626
Resident Engineer: Artin Merati Structure Rep.: Michael Yee
Sample Information
DIME Sample ID: 2026-06-01-76
TL Number from the TL Form:
Sample Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Sample Organization Contact: 9492798846
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 06/01/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/02/2026
The quantity of what the sample constitutes: 3
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 26-0112
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Short Load Concrete
Material Information
The concrete mix design number: CTS-65-EHI
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: Unknown
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Discharge from concrete truck into wheelbarrow.
Where the material sample would have been placed if not sampled: NB 5 Crown Valley To 405/5 (HOV, Lane# 1 & 2)
From Lot No.:
Bag Lot No.:
Test Results
Test
DIME Test ID: 2026-06-01-76-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 06/11/2026
Date Tested: 06/11/2026
Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Organization Address: 19601 Beach Boulevard,
Organization City: Huntington Beach
Organization State: CA
Organization Zipcode: 92648
Organization Email: frank.mai@dot.ca.gov
Organization Phone: (949) 279-8846
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Average diameter of cylinder 1
|
6.00 in
|
|
Average diameter of cylinder 2
|
6.01 in
|
|
Average diameter of cylinder 3
|
6.00 in
|
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
|
Cross sectional area of cylinder 2
|
28.37 in^2
|
|
Cross sectional area of cylinder 3
|
28.27 in^2
|
|
Compressive strength (to nearest 10 psi)
|
6820 psi
|
|
Maximum load on cylinder 1
|
197710 lb
|
|
Maximum load on cylinder 2
|
192120 lb
|
|
Maximum load on cylinder 3
|
188840 lb
|
|
Compressive strength of cylinder 1
|
6993.6 psi
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Compressive strength of cylinder 2
|
6771.9 psi
|
|
Compressive strength of cylinder 3
|
6679.9 psi
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Type of fracture pattern of cylinder 3
|
3
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
10 days
|
|
Age of specimen in hours
|
no data0 hours
|