Print Report | Back to Sample Detail

Sample Record for 2026-06-10-12

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001360 DEA: 09374804 EFIS: 0918000020 QA Service Level: 1
DIST-CO-RTE-PM: 09-INY-395-115.0
Work Description: BUILDING WORK AND PLACE HMA (TYPE A).
Location Description: INYO COUNTY IN BISHOP AT THE DISTRICT OFFICE AT 500 SOUTH MAIN STREET
Contractor Name: BOWE CONTRACTORS INC.
Contractor Address: 609 Bailey Ct, Tehachapi, CA 93561
Resident Engineer: David Carruba Structure Rep.: Mulugheta Belay

Sample Information

DIME Sample ID: 2026-06-10-12
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 06/10/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/23/2026
The quantity of what the sample constitutes: 25
A brief description of the sample: 5/8"-13 X 1.5"
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cordova Bolt Inc. Buena Park, CA.

Material Information

Rocap Number(s): N/A
Heat Number(s): 1000225917 256490 12511080
Nut Mfg. Lot Number(s): 42595-256490
Washer Mfg. Lot Number(s): 0725-732
Bolt Specification: ASTM A325
Bolt Length(s): 1.5
Nut Specification: A563
Washer Specification: F436
Finish: Black
Diameter/Size: 5/8""
Bolt Mfg. Lot Number: W000219204
Rocap Test Requirement(s): No
Lubricant Requirements(s): Yes
Washer Inner Diameter(s): five eight

Test Results

Test

DIME Test ID: 2026-06-10-12-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 07/09/2026
Date Tested: 07/08/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number W000219204
Finish Coating Plain
Product Markings no data
Size 0.625 in
Bolt Length 1.5 in
Pitch Diameter 0.5620 in
Pitch Diameter 2nd no data in

Test

DIME Test ID: 2026-06-10-12-2
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 07/09/2026
Date Tested: 07/08/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 0725-732
Finish Coating Plain
Product Markings no data
Size 0.625 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 41
Spacing Ok

Test

DIME Test ID: 2026-06-10-12-3
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 07/09/2026
Date Tested: 07/08/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
1AW0002192040.6253186000Bolt TensileKleinfelder
UTM NA
Temperature 0 f

Test

DIME Test ID: 2026-06-10-12-4
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 07/09/2026
Date Tested: 07/08/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
1A42595-2564900.6253955000Nut Proof LoadKleinfelder
UTM NA
Temperature 0 f