Print Report | Back to Sample Detail

Sample Record for 2026-06-10-11

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001360 DEA: 09374804 EFIS: 0918000020 QA Service Level: 1
DIST-CO-RTE-PM: 09-INY-395-115.0
Work Description: BUILDING WORK AND PLACE HMA (TYPE A).
Location Description: INYO COUNTY IN BISHOP AT THE DISTRICT OFFICE AT 500 SOUTH MAIN STREET
Contractor Name: BOWE CONTRACTORS INC.
Contractor Address: 609 Bailey Ct, Tehachapi, CA 93561
Resident Engineer: David Carruba Structure Rep.: Mulugheta Belay

Sample Information

DIME Sample ID: 2026-06-10-11
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 06/10/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/23/2026
The quantity of what the sample constitutes: 55
A brief description of the sample: 5/8"-13 X 6"
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cordova Bolt Inc. Buena Park, CA.

Material Information

Rocap Number(s): N/A
Heat Number(s): 1000124540 256490 12511080
Nut Mfg. Lot Number(s): 42595-256490
Washer Mfg. Lot Number(s): 0725-732
Bolt Specification: ASTM A325
Bolt Length(s): 6"
Nut Specification: A563
Washer Specification: F436
Finish: Black
Diameter/Size: 5/8""
Bolt Mfg. Lot Number: W000156650
Rocap Test Requirement(s): No
Lubricant Requirements(s): Yes
Washer Inner Diameter(s): five eight

Test Results

Test

DIME Test ID: 2026-06-10-11-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 07/09/2026
Date Tested: 06/24/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 1000124540
Mfg. Lot Number L196-061-26
Finish Coating Plain
Product Markings A325 USA U
Size 0.625 in
Bolt Length 6.0 in
Pitch Diameter 0.5615 in
Pitch Diameter 2nd no data in

Test

DIME Test ID: 2026-06-10-11-2
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 07/09/2026
Date Tested: 06/24/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 1000124540
Mfg. Lot Number L196-061-26
Finish Coating Plain
Product Markings A325 USA U
Size 0.625 in
Bolt Length 6.0 in
Pitch Diameter 0.5615 in
Pitch Diameter 2nd no data in

Test

DIME Test ID: 2026-06-10-11-3
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 07/09/2026
Date Tested: 07/08/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 0725-732
Finish Coating Plain
Product Markings no data
Size 0.625 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 41
Spacing Ok

Test

DIME Test ID: 2026-06-10-11-4
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 07/09/2026
Date Tested: 07/08/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 0725-732
Finish Coating Plain
Product Markings no data
Size 0.625 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 41
Spacing Ok

Test

DIME Test ID: 2026-06-10-11-5
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 07/09/2026
Date Tested: 07/08/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
1AW0001566500.6253076000Bolt TensileKleinfelder
UTM NA
Temperature 0 f

Test

DIME Test ID: 2026-06-10-11-6
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 07/09/2026
Date Tested: 07/08/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
1A42595-2564900.6253955000Nut Proof LoadKleinfelder
UTM NA
Temperature 0 f