Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1001683 DEA: 040AA194 EFIS: 0419000450
QA Service Level: 1
DIST-CO-RTE-PM: 04-CC-4-R29.0/R44.4
Work Description: COLD PLANE AC PVMT, RHMA-G & HMA OVERLAY, REPLACE AC SURF, & MGS.
Location Description: CONTRA COSTA COUNTY IN ANTIOCH AND AT BYRON FROM HILLCREST AVENUE OVERCROSSING TO BYRON HIGHWAY
Contractor Name: GHILOTTI BROS INC
Contractor Address: 523 JACOBY ST, SAN RAFAEL, CA 94901
Resident Engineer: Steven Lee Structure Rep.: Unknown
DIME Sample ID: 2026-05-26-27
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Concord Field Laboratory
Sample Organization Contact: (510) 714-7019
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/26/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/04/2026
The quantity of what the sample constitutes: 4 boxes
A brief description of the sample: 1/2" WMA-RAP 25
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Teichert Materials Vernalis
DIME Test ID: 2026-05-26-27-1
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 06/09/2026
Date Tested: 06/04/2026
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test: NO. 8 is below the operating range
Test Result Compliance: does not comply
Additional Comments When Verified:
|
Is an aggregate correction factor used?
|
No
|
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
|
Cumulative percent passing the 1/2 in. sieve
|
95 %
|
|
Cumulative percent passing the 3/8 in. sieve
|
85 %
|
|
Cumulative percent passing the #4 sieve
|
56 %
|
|
Cumulative percent passing the #8 sieve
|
36 %
|
|
Cumulative percent passing the #16 sieve
|
22 %
|
|
Cumulative percent passing the #30 sieve
|
15 %
|
|
Cumulative percent passing the #50 sieve
|
10 %
|
|
Cumulative percent passing the #100 sieve
|
7 %
|
|
Cumulative percent passing the #200 sieve
|
5.1 %
|
DIME Test ID: 2026-05-26-27-2
Test Method: AASHTO T209-25: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 06/09/2026
Date Tested: 06/04/2026
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Specific Gravity for Sample 1
|
2.442
|
|
Theoretical maximum density at 25°C (77°F)
|
2435 kg/m^3
|
DIME Test ID: 2026-05-26-27-3
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/09/2026
Date Tested: 06/04/2026
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Corrected Asphalt Binder Content
|
5.43 %
|
|
Mass of HMA Sample prior to ignition
|
1583 g
|
|
Mass Loss
|
102.1 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.86 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.16 %
|
|
Test Temperature
|
482 C
|