Sample Record for 2026-06-03-53
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1001640 DEA: 010N2904 EFIS: 0123000202
QA Service Level: 1
DIST-CO-RTE-PM: 01-DN-197,199-Var
Work Description: REPLACE BRIDGE, EXCAVATION, AND RETAINING WALLS.
Location Description: DEL NORTE COUNTY AT VARIOUS LOCATIONS
Contractor Name: McCullough Construction, Inc.
Contractor Address: 57 Aldergrove Rd, Arcata, CA 95521
Resident Engineer: Aaron Valley Structure Rep.: Joshua Lee
Sample Information
DIME Sample ID: 2026-06-03-53
TL Number from the TL Form:
Sample Submitted By Organization: CT D01 - Crescent City Field Laboratory
Sample Organization Contact: (707) 496-5581
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 06/03/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/05/2026
The quantity of what the sample constitutes: 54 CY
A brief description of the sample: Concrete
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tidewater Starry pit
Material Information
The concrete mix design number: S-C2
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 3628
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Discharged from concrete truck into wheelbarrow.
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test
DIME Test ID: 2026-06-03-53-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 06/17/2026
Date Tested: 06/17/2026
Submitted By Organization: CT D01 - Crescent City Field Laboratory
Organization Address: 1444 Parkway Dr.,
Organization City: Crescent City
Organization State: CA
Organization Zipcode: 95531
Organization Email: clayton.malmberg@dot.ca.gov
Organization Phone: (707) 496-5581
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
1
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Compressive strength of cylinder (to nearest 10 psi)
|
4680 psi
|
|
Maximum load on cylinder 1
|
58817 lb
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Age of specimen
|
14 days
|
|
Age of specimen in hours
|
no data0 hours
|