Print Report | Back to Sample Detail

Sample Record for 2026-06-02-58

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001153 DEA: 081L3104 EFIS: 0820000020 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-74-11.8/17.3
Work Description: RHMA (GAP GRADED), REPLACE AC SURF, AND COLD PLANE AC PVMT.
Location Description: RIVERSIDE COUNTY IN LAKE ELSINORE FROM GRAND AVENUE TO ROUTE 15/74 SEPARATION
Contractor Name: R.J. NOBLE COMPANY
Contractor Address: Unknown
Resident Engineer: Xavier Avila Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-06-02-58
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/02/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/03/2026
The quantity of what the sample constitutes: 2 boxes
A brief description of the sample: 1/2" RWMA-G-SP
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RJ Noble Company

Material Information

HMA Type: RHMA-G
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number:
Binder content (%): 0.0
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test

DIME Test ID: 2026-06-02-58-1
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/08/2026
Date Tested: 06/05/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Corrected Asphalt Binder Content 7.89 %
Mass of HMA Sample prior to ignition 2154 g
Mass Loss 182.3 g
Correction Factor (Percent by mass of HMA Specimen) 0.43 %
Moisture Content no data0 %
Temperature Compensation Factor 0.14 %
Test Temperature 538 F