Print Report | Back to Sample Detail

Sample Record for 2026-04-17-55

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1001468 DEA: 081L2404 EFIS: 0819000167 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-95-R57.2/64.5
Work Description: RHMA (GAP GRADED), REPLACE AC SURFACING, AND COLD PLANE AC PVMT.
Location Description: SAN BERNARDINO COUNTY NEAR NEEDLES FROM ROUTE 40/95 SEPARATION TO 0.5 MILE NORTH OF GOFFS ROAD
Contractor Name: SULLY - MILLER CONTRACTING COMPANY
Contractor Address: 135 S STATE COLLEGE BLVD. 400, BREA, CA 92821
Resident Engineer: Anthony Doan Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2026-04-17-55
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 04/17/2026
Date that the sample was received by the laboratory/organization performing the testing: 04/18/2026
The quantity of what the sample constitutes: 1can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Blue Diamond-Victorville

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test

DIME Test ID: 2026-04-17-55-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 06/08/2026
Date Tested: 06/03/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 65 C
Softening Point Sample 2 65 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data

Test

DIME Test ID: 2026-04-17-55-2
Test Method: ASTM D217-21: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 06/08/2026
Date Tested: 06/04/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination Prolonged Worked Penetration
Prolonged Worked Penetration 28 0.1 mm

Test

DIME Test ID: 2026-04-17-55-3
Test Method: ASTM D5329-20: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 06/08/2026
Date Tested: 06/04/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Ball Penetration (P1) 1 mm
Final Dial reading (F1) 49 mm
Ball Penetration (P2) 1 mm
Final Dial reading (F2) 50 mm
Ball Penetration (P3) no data0 mm
Final Dial reading (F3) 49 mm
Resilience 1 52 %
Resilience 2 51 %
Resilience 3 51 %
Average Resilience 51 %
Minutes Reaction no data