Sample Record for 2026-06-03-42
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1001469 DEA: 120K62U4 EFIS: 1224000090
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA, -5-R25.8/30.3
Work Description: CONST BRIDGE, RW, SW, PAVEMENT, DRAINAGE, AND ELECTRICAL SYSTEMS.
Location Description: ORANGE COUNTY IN IRVINE AND TUSTIN FROM YALE AVENUE OVERCROSSING TO ROUTE 5/55 SEPARATION
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 16700 Valley View Avenue Suite 300, La Mirada, CA 90638
Resident Engineer: Carter Cox Structure Rep.: Younho Rew
Sample Information
DIME Sample ID: 2026-06-03-42
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (213) 505-4213
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 06/03/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/05/2026
The quantity of what the sample constitutes: 150
A brief description of the sample: HRC 500/510 Coupler
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Field
Material Information
Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: Cascade
Coupler Manufacturer: HRC
Intermediate Assembler or Fabricator:
Rebar Size: #14
Coupler Model: HRC 5//510
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter:
Rebar Hoop Fabricator:
Coupler Component Heat/Lot Number(s): 73140308, 73140828
Rebar Heat Number(s): 534725
Rebar Size 2 :
Coupler Unique ID: TP-17-03
Test Results
Test
DIME Test ID: 2026-06-03-42-2
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Verified Date: 06/09/2026
Date Tested: 06/08/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
4
|
| Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | | 1 | 1 | 14 | 2.25 | 0.017 | 224500 | 100000 | NA | Kleinfelder | | 2 | 1 | 14 | 2.25 | 0 | 220600 | 98000 | NA | Kleinfelder | | 3 | 1 | 14 | 2.25 | 0 | 225250 | 100000 | NA | Kleinfelder | | 4 | 1 | 14 | 2.25 | 0 | 223050 | 99000 | NA | Kleinfelder |
| |
|
Temperature
|
0 f
|
|
UTM
|
NA
|
|
Halo ID
|