Print Report | Back to Sample Detail

Sample Record for 2026-06-04-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1002104 DEA: 07369604 EFIS: 0719000376 QA Service Level: 1
DIST-CO-RTE-PM: 07-UNKNOWN--unknown
Work Description:
Location Description:
Contractor Name: Peterson Chase Construction
Contractor Address: 16351 Construction Circle West, Irvine, CA 92606
Resident Engineer: Nzhde Matecosyan Structure Rep.: Adriana Pimienta

Sample Information

DIME Sample ID: 2026-06-04-6
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 06/04/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/18/2026
The quantity of what the sample constitutes: 800
A brief description of the sample: 2" x 5' Anchor Bolt
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Universal Industrial Sales

Material Information

Rocap Number(s): N/A
Heat Number(s): 1201072765
Nut Mfg. Lot Number(s): N/A
Washer Mfg. Lot Number(s): N/A
Bolt Specification: F1554 Gr. 55
Bolt Length(s): 5'
Nut Specification: N/A
Washer Specification: N/A
Finish: HDG
Diameter/Size: 2"
Bolt Mfg. Lot Number: 1201072765
Rocap Test Requirement(s): 0
Lubricant Requirements(s): 0
Washer Inner Diameter(s): 0

Test Results

Test

DIME Test ID: 2026-06-04-6-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 07/07/2026
Date Tested: 07/07/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 1201072765
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 2 in
Bolt Length 60 in
Pitch Diameter 1.900 in
Pitch Diameter 2nd no data in

Test

DIME Test ID: 2026-06-04-6-2
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 07/07/2026
Date Tested: 07/07/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 1201072765
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 2 in
Bolt Length 60 in
Pitch Diameter 1.887 in
Pitch Diameter 2nd no data in

Test

DIME Test ID: 2026-06-04-6-3
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 07/07/2026
Date Tested: 07/07/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) 1201072765
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 2 in
Bolt Length 60 in
Pitch Diameter 1.890 in
Pitch Diameter 2nd no data in

Test

DIME Test ID: 2026-06-04-6-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/07/2026
Date Tested: 07/07/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 1201072765
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 2 in
Bolt Length 60 in
Measurement Average 8.5 mils

Test

DIME Test ID: 2026-06-04-6-5
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/07/2026
Date Tested: 07/07/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 1201072765
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 2 in
Bolt Length 60 in
Measurement Average 8.7 mils

Test

DIME Test ID: 2026-06-04-6-6
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/07/2026
Date Tested: 07/07/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) 1201072765
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 2 in
Bolt Length 60 in
Measurement Average 9 mils

Test

DIME Test ID: 2026-06-04-6-7
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 07/07/2026
Date Tested: 07/07/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 2
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
1A1201072765219814000000yield 161250Kleinfelder
1B1201072765219944000000yield 166240Kleinfelder
UTM NA
Temperature 0 f