Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1001960 DEA: 081J65U4 EFIS: 0824000091
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-10-0.0/R8.2
Work Description: HMA, RHMA, JPCP, JPCP(RSC), and individual slab replacement (RSC).
Location Description:
Contractor Name: Flatiron Dragados
Contractor Address: 12121 scripps Summit Drive, suite 400, Sandeigo, CA 92131
Resident Engineer: Sadique Hossain Structure Rep.: Unknown
DIME Sample ID: 2026-05-18-55
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Binder
Sample Taken Date: 05/18/2026
Date that the sample was received by the laboratory/organization performing the testing: 05/19/2026
The quantity of what the sample constitutes: 1can
A brief description of the sample: Asphalt Binder Sample
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: All American Asphalt Corona
Performance Grade: PG 64-10
Modified:
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: San Joaquin Refinery - Bakersfield CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:
DIME Test ID: 2026-05-18-55-4
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/03/2026
Date Tested: 06/01/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Phase
|
Original binder
|
|
Phase Angle (δ) (for the 10 cycles)
|
87.5 degree
|
|
Dynamic Shear, G*/sin(δ)
|
1.30 kPa
|
DIME Test ID: 2026-05-18-55-3
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/03/2026
Date Tested: 06/01/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Phase
|
RTFO residue
|
|
Phase Angle (δ) (for the 10 cycles)
|
84.4 degree
|
|
Dynamic Shear, G*/sin(δ)
|
3.55 kPa
|
DIME Test ID: 2026-05-18-55-2
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 07/03/2026
Date Tested: 06/01/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Is mass change based on one or two containers?
|
Two
|
|
Is mass change correction factor needed?
|
Yes
|
|
Any material loss from containers during heating process/testing?
|
No
|
|
Mass of container #1 before test (m1i)
|
203.277 grams
|
|
Mass of container #2 before test (m2i)
|
206.84 grams
|
|
Mass of container #1 after test (m1f)
|
203.211 grams
|
|
Mass of container #2 after test (m2f)
|
206.781 grams
|
|
Average mass change
|
-0.173 percent
|
|
Mass of empty container #1
|
168.205 grams
|
|
Mass of empty container #2
|
171.918 grams
|
|
Mass correction factor
|
0.006
|
DIME Test ID: 2026-05-18-55-6
Test Method: AASHTO T44-23: Standard Method of Test for Solubility of Bituminous Materials
Verified Date: 07/03/2026
Date Tested: 06/01/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Was test performed on residue from distillation or evaporation?
|
Distillation
|
|
Soluble, percent
|
99.8 %
|
|
Insoluble, percent
|
0.1 %
|
DIME Test ID: 2026-05-18-55-5
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Verified Date: 07/03/2026
Date Tested: 06/01/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Is viscosity reading in cP/Pa-s?
|
Pa-s
|
|
Time of test
|
7:05 HH:MM
|
|
Test Temperature
|
135 C
|
|
Speed
|
100 rpm
|
|
Spindle size
|
21 in
|
|
Torque
|
70.4 %
|
|
Viscosity reading #1 (A)
|
0.348 Pa-s
|
|
Viscosity reading #2 (B)
|
0.353 Pa-s
|
|
Viscosity reading #3 (C)
|
0.357 Pa-s
|
|
Average viscosity
|
0.353 Pa-s
|
DIME Test ID: 2026-05-18-55-1
Test Method: AASHTO T228-22: Standard Method of Test for Specific Gravity of Semi-Solid Asphalt Materials (Specific Gravity)
Verified Date: 07/03/2026
Date Tested: 06/01/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2026-05-18-55-7
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Verified Date: 07/03/2026
Date Tested: 06/02/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Is a normal test obtainable?
|
Yes
|
|
Number of replicates tested
|
One
|
|
Ductility of test #1 (D1)
|
75 cm
|
|
Ductility of sample
|
75 cm
|
DIME Test ID: 2026-05-18-55-8
Test Method: AASHTO T313-2025: Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 07/03/2026
Date Tested: 07/01/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Maximum test bath temperature at 240 S
|
0.0 C
|
|
Minimum test bath temperature at 240 S
|
0.0 C
|
|
Estimated Stiffness Modulus 8.0 s
|
0.000 MPa
|
|
Estimated m-value 8.0 s
|
0.000
|
|
Estimated Stiffness Modulus 15.0 s
|
0.000 MPa
|
|
Estimated m-value 15.0 s
|
0.000
|
|
Estimated Stiffness Modulus 30.0 s
|
0.000 MPa
|
|
Estimated m-value 30.0 s
|
0.000
|
|
Estimated Stiffness Modulus 60.0 s
|
293.242 MPa
|
|
Estimated m-value 60.0 s
|
0.352
|
|
Estimated Stiffness Modulus 120.0 s
|
0.000 MPa
|
|
Estimated m-value 120.0 s
|
0.000
|
|
Estimated Stiffness Modulus 240.0 s
|
0.000 MPa
|
|
Estimated m-value 240.0 s
|
0.000
|
DIME Test ID: 2026-05-18-55-9
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/03/2026
Date Tested: 07/01/2026
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Phase
|
PAV residue
|
|
Test Plate Diameter
|
8 mm
|
|
Phase Angle (δ) (for the 10 cycles)
|
53.0 degree
|
|
(G*) x sin(δ)=
|