Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000511 DEA: 06487404 EFIS: 0616000029
QA Service Level: 1
DIST-CO-RTE-PM: 06-TUL-99-35.8/37.1
Work Description: Caldwell Interchange SR99/Ave280 (Visalia) - Replace Bridge Structures and Construct Roundabouts.
Location Description: TULARE COUNTY IN AND NEAR VISALIA FROM 0.6 MILE SOUTH OF AVENUE 280 OVERCROSSING TO 0.7 MILE NORTH OF AVENUE 280 OVERCROSSING
Contractor Name: Granite Construction Company (Karen Cervantes)
Contractor Address: 2716 Granite Court, Fresno, CA 93706
Resident Engineer: Alberto Lopez Structure Rep.: Martin Garcia
DIME Sample ID: 2026-05-29-22
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (213) 505-4213
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 05/29/2026
Date that the sample was received by the laboratory/organization performing the testing: 06/01/2026
The quantity of what the sample constitutes: 3400
A brief description of the sample: A325 Bolt
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: QFC Industries
Rocap Number(s): NA
Heat Number(s): 10994980
Nut Mfg. Lot Number(s): NA
Washer Mfg. Lot Number(s): NA
Bolt Specification: A325
Bolt Length(s): 1.75
Nut Specification: NA
Washer Specification: NA
Finish: HDG
Diameter/Size: 0.625
Bolt Mfg. Lot Number: E775X1
Rocap Test Requirement(s): NA
Lubricant Requirements(s): NA
Washer Inner Diameter(s): NA
DIME Test ID: 2026-05-29-22-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 07/07/2026
Date Tested: 06/01/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E775X1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
A325 LE USA
|
|
Size
|
0.625 in
|
|
Bolt Length
|
1.75 in
|
|
Pitch Diameter
|
0.5740 in
|
|
Pitch Diameter 2nd
|
no data in
|
DIME Test ID: 2026-05-29-22-2
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 07/07/2026
Date Tested: 06/01/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E775X1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
A325 LE USA
|
|
Size
|
0.625 in
|
|
Bolt Length
|
1.75 in
|
|
Pitch Diameter
|
0.5760 in
|
|
Pitch Diameter 2nd
|
no data in
|
DIME Test ID: 2026-05-29-22-3
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 07/07/2026
Date Tested: 06/01/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E775X1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
A325 LE USA
|
|
Size
|
0.625 in
|
|
Bolt Length
|
1.75 in
|
|
Pitch Diameter
|
0.5740 in
|
|
Pitch Diameter 2nd
|
no data in
|
DIME Test ID: 2026-05-29-22-4
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 07/07/2026
Date Tested: 06/01/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1D
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E775X1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
A325 LE USA
|
|
Size
|
0.625 in
|
|
Bolt Length
|
1.75 in
|
|
Pitch Diameter
|
0.575 in
|
|
Pitch Diameter 2nd
|
no data in
|
DIME Test ID: 2026-05-29-22-5
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/07/2026
Date Tested: 06/29/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E775X1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
3.4 mils
|
DIME Test ID: 2026-05-29-22-6
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/07/2026
Date Tested: 06/29/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E775X1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.7 mils
|
DIME Test ID: 2026-05-29-22-7
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/07/2026
Date Tested: 06/29/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E775X1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
3.2 mils
|
DIME Test ID: 2026-05-29-22-8
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 07/07/2026
Date Tested: 06/29/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1D
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
E775X1
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
3 mils
|
DIME Test ID: 2026-05-29-22-9
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 07/07/2026
Date Tested: 06/29/2026
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Bolt Samples
|
3
|
| Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | | 1A | E775X1 | 0.625 | 32595 | 0 | 0 | NA | WSP | | 1B | E775X1 | 0.625 | 31355 | 0 | 0 | NA | WSP | | 1C | E775X1 | 0.625 | 32335 | 0 | 0 | NA | WSP |
| |
|
UTM
|
NA
|
|
Temperature
|
0 f
|