Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 101J3204 Cty SJ Rte 99 PM 30.73 Vendor # |
|
REPORT OF LABORATORY TESTING |
||||
|
Resident Engineer: |
Ranbir Bhullar |
Date Reported: |
02/22/2018 |
|
|
Address: |
TL Number: |
131009 |
||
|
City: |
||||
|
Project Name: Remove and replace damaged girder 1 in Span 2 |
||||
|
Prime Contractor: Not set |
||||
|
Sample Taken Date: |
02/08/2018 |
Mix Design: |
000000000000000000 |
|
|
Contractor: Unknown |
Location : |
|||
|
Structure unique identifier: Unknown |
||||
|
Structure name: Unknown |
||||
|
Location of Pour: Unknown |
||||
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 5.97 | 27.99 | 115004 | 4108.8 | 2 |
| 2 | 5.97 | 27.99 | 114427 | 4088.1 | 1 |
DIME Test ID: 2018-02-08-5-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4100
Age of specimen: 14 days
Certified By: Bang Nguyen
|
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing